Dicas Reparação GRUNDIG




Modelo - Chassis


Pesquisa: GRUNDIG Enviar Dica Resolvida
Resultados 797
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
GrundigCUC6310
dead - led flashesT568 lop tr s/c - replacement failed - C969 9n o/c (blue box type)
GrundigCUC6310
Dead lop tr BU508AG s/c
GrundigCUC6300
Reverts to st/by aft 3 secsPin 8 IC811 going low (overvolts prot) - caused by crack in print between conn C & C591/2
GrundigCUC6300
Audio int comes & goesCheck st/by contacts on mains sw (dis to isolate)
GrundigCUC60
No frame - D406 burning up.C643 ( 1000uf 40V ) on frame PCB , D406 ( RGP10G )
GrundigCUC5835
Goes straight to st/by at sw onCheck for field faults - R7021 4R7 o/c, IC7020 s/c, also replace C7027 220µ 35v flyback cap
GrundigCUC5365
R793 330R burnt up on crt baseTEA5101A replaced & mod - connect aquadag lead to middle of wire under scan coils & cut lead short as poss. add res 150K from coll T593 to chassis
GrundigCUC5361
trips on high brill - no beam lim actionbeam lim volts to pin 12 RGB module. Volts at pin 15 IC5150 should fall as brill increases. It did but chip was u/s
GrundigCUC5361
Int rolling/shaking picDry joints on earthing frame of chassis
GrundigCUC5360
Store ,tuning , analogue controls inoperativeCheck memory Ics IC847/8 also bad earths which could be cause of Ics going faulty
GrundigCUC5360
No vid via scart sktSw carried out in tuner/IF chip. Check CT2512/3/4/7 sm types BC848/858
GrundigCUC5360
int tunercheck for dry joints on xtal
GrundigCUC5360
Col intReplace 4.43Mhz red trimmer
GrundigCUC5360
No NICAM sound - whistle on mono soundMSP2400 chip in IF module
GrundigCUC5350 CUC5360
"P1" DISPLAYED AFTER PROCESSOR CHANGEDR836 FROM 10K TO 22K ( OLD SDA 20562 A 006 NEW SDA 20562 A 506 Grundig 8305-157-580 )


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.