Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Grundig | CUC2410 | No sound - may have had a flash over. | IC TDA2595 | ||
Grundig | CUC2410 | NO SOUND | TDA2595 MUTING SET | ||
Grundig | CUC2410 | no pic, sound & txt ok blank raster | no vid i/p at pin 8 TDA3566 - BC 548C Tr2523 s/c c-e | ||
Grundig | CUC2410 | dead - spillage | Replace 1.25 & 2.5A fuses, chopper tr BU508A. Now works but R616 2k7 start up res overheats - R617 thermistor u/s. Code 07902 - WVE | ||
Grundig | CUC2410 | AGC fault - dist pic on good signal | Video discriminator coil on IF F2211 | ||
Grundig | CUC2401 | Trips at sw on | L519 shorted turns | ||
Grundig | CUC2401 | Tripping - at switch on. | R637 1k control. | ||
Grundig | CUC2401 | Tripping - at switch on - may come on. | C661 ( 7u f , 25v ) | ||
Grundig | CUC2401 | Switching to standby - my take days. | Tripler. | ||
Grundig | CUC2401 | Startup - failure to start intermittent. | Set HT R637 ( 1k ) may ch Ok , LOPTX if going off af few mins | ||
Grundig | CUC2401 | Standby - intermittent shut down. | Set HT control R637 ( 1k ) may check Ok. | ||
Grundig | CUC2401 | Sound - mutes on video rec playback. | Mod ABL module. | ||
Grundig | CUC2401 | SET GOES TO STBY VERY INT | TRIPLER US | ||
Grundig | CUC2401 | No sound or - Picture - intermittent. | Suspect the set-EHT control ( especially if made by Preh. | ||
Grundig | CUC2401 | No sound | Could be TDA2595, TDA130 or SDA2011-A003 micro |