HitachiNP83CQ
deadwon't work on dummy load unless loptx removed - loptx faulty
HitachiNP83CQ
dead2A fuse blackened, STR6020 s/c, Loptx s/c windings, 2 x 1R safety re o/c (no 12v or 30v) & TDA3651 field chip u/s
HitachiNP83CQ
Channels - no channel change & no raster.Q1454 ( cita Pcb )
HitachiNP83CQ
Bright on LH side of rasterC715 2µ2 250v o/c
HitachiNP83CGMk2
Pic pulls to right & int field rollTry s/c vid in & out conns on txt pcb - if ok fault on txt pcb
HitachiNP83
Standby - stuck in standby mode.R1437 ( 820R ) o/c change to 1w type.
HitachiNP83
No sound.R462 ( 22R ) o/c.
HitachiNP83
FIELD COLLAPSE FIELD SQUARE WAVE PRESENT AT PIN 4C610 220uF 50v
HitachiNP83
Channels - no channel change & blank raster.Q1454 ( cita Pcb )
HitachiNP82CQ2
Standby - int going into standby.IC901 ( STR6020 )
HitachiNP82CQ/2
Whistle - loud whistle & ragged verticals.IC701 ( LA7801 )
HitachiNP82CQ/2
Tripping.IC701 , IC681 , Q681 , IC901.
HitachiNP82CQ/2
Standby - going into standby.IC901 ( STR6020 )
HitachiNP82CQ/2
Sparking inside set.R902/3 ( 82k , 0.5w ) , IC701 ( LA7801 ) , IC901 ( STR6020
HitachiNP82CQ/2
Ragged verticals & loud whistle.IC701 ( LA7801 )


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.