HitachiNP81CQ
Splutteringdry joints loptx earth pin
HitachiNP81CQ
Small faint raster.C909 ( 220u f 160v )
HitachiNP81CQ
No/Int loss of colour.L506 ( P No 2160831 )
HitachiNP81CQ
Int frame collapse.Drys R607.
HitachiNP81CQ
Int colourdelay gate pulse coil L506 faulty
HitachiNP81CQ
Hum on picture - varies with picture.Fit 22k in series with D402 if not fitted.
HitachiNP81CQ
HIGH BRILL VERY INTZD802 5.1v ZENER ON CRT BASE
HitachiNP81CQ
Frame - int frame collapse/top crampingC608 ( 22u f )
HitachiNP81CQ
Frame - foldover at top.C610 ( 220u f )
HitachiNP81CQ
Flyback lines on picture.C715 ( 4.7u f 250v )
HitachiNP81CQ
Field bounce esp on chan change & hi contrastC601 220µ 50v u/s
HitachiNP81CQ
Dead.R905 ( 56R 3w ) o/c , R906 ( 82R 2w ) o/c.
HitachiNP81CQ
deadMains fuse o/c; pin 6 chopper tfmr burnt, STK411, Q901 2SD787; R904 82K hi res, D901 2v7 zener s/c, D902 33v zener o/c, lop tr s/c, TDA1035S sound chip u/s
HitachiNP81CQ
Dark pic 1st Anode low 200VC714 ( 0.068uF ) 1KV o/c
HitachiNP81CQ
Bright white screenCheck V at K2 on CRT base if low replace C715 ( 4.7uF )


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.