HitachiG8Q
excess brill / fb lines200v video supply missing - R720 2R0 o/c
HitachiG8Q
EEPROM keeps becoming corruptedDeguassing positor int arcing
HitachiG8Q
Display corruptCheck Q1502/3/4/5 - Q1505 was leaky BC548
HitachiG8Q
Diagonal bands of interference - esp in TxtC932 470µ 16v
HitachiG8Q
DEAD WITH LINE DRIVER TURNED FULLY ON AND LED NOTCHECK AROUND IC1502 ( SAA1293 ) FOR ACTIVITY if none replace X1501 crystal
HitachiG8Q
Dead with blackened mains fuseMelted PVC tape from degaussing coils touching audio amps heatsink
HitachiG8Q
Dead or int start up/offStart up therm TH902 o/c
HitachiG8Q
Dead- fuse blackenedCheck TH902 thermistor
HitachiG8Q
Dead apart from trippingTxt panel dis'd & trip stops - C933
HitachiG8Q
Dead apart from chan no.12v supply only 5v - C933 2200µ 25v
HitachiG8Q
Dead after smokingC715 in E-W cct dry joints
HitachiG8Q
Dead - went off with abangTH902, also check Q901, Q902, ZD901, ZD903, D905, D907, D908 IC901, C908 , R910 & check print
HitachiG8Q
Dead - no PSU operationD907 BYV10-40 s/c also check UC3844 & Q901/2
HitachiG8Q
Dead - no line driveTimebase chip TDA2579 faulty - no line drive o/p at pin 11
HitachiG8Q
Dead - intermittently.Drys on T901 , D933 or LOPTX.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.