Dicas Reparação HITACHI




Modelo - Chassis


Pesquisa: HITACHI Enviar Dica Resolvida
Resultados 1003
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
HitachiG7P
DEAD WITH ONLY 33v AT LINE OP. COLL.CHECK MAIN SMOOTHING 150mfd 400v C909
HitachiG7P
DEAD SURGE LIMITER O/C 3R9 7W Q901 OKC919 4n7 1kv SC
HitachiG7P
Dead int & blows chopper trR932 220k to pin 4 TDA4601 hi res
HitachiG7P
Dead - mains fuse o/c - chopper tr s/cCheck R931 150k & R932 120k
HitachiG7P
Dead - HT low at 26v until LOP stage dis'dD905 MPG06J leaky
HitachiG7P
deadLOP tr 2SD1884 s/c - use correct type
HitachiG7P
DeadCHECK DIODE ACROSS BASE EMITTER OF CHOPPER TRANSISTOR
HitachiG7P
DeadCHECK R901 ( 3R9 ) 7W C919 ( 4.7nF ) 1Kv AND C928 ( 2.2nF ) 2Kv R932 R931 ( 100K ) Q901 ( BUT11 ) D904
HitachiG7P
CUTS OUT INTR919 920 100k
HitachiG7P
Cuts out aft half hourProt thy triggers due to Q704 BF432 leaky when warm
HitachiG7P
Crowbar operates aft 5 secs aft Loptx replacementZD703 faulty - measured ok out of cct
HitachiG7P
COMES ON BRIGHT THEN TRIPS OFFQ801 BC558 OR ZD804 9v1
HitachiG7P
Black lines across screen & int field collapsedry joints field o/p chip IC601
HitachiG7P
Bent verts at top when playing tapesTry changing C104 to 22µ & C205 to 4µ7 - if this makes no difference, reduce C701 to 3n3 & C702 to 0µ47 50v (unofficial)
HitachiG7/8QP
WHITE SCREENREFIT C171


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.