HitachiG6P CPT2476
Dead apart from slight noise from psuHT reads 25v - 50v when LOP dis'd ; D902 dry joints
HitachiG6P CPT2178
Sync - line & field int lostIC2110 5v reg dry joints
HitachiG6P
Won't memorise chansNo -30v to IC1102 - R772 1k2 hi res
HitachiG6P
Whistling psu - esp on bright scenesC909 220µ 160v HT smoothing cap low cap
HitachiG6P
VARYING SOUND LEVELZD791 ZENER HZ11LC2 IN Q791 BASE CIRCUIT
HitachiG6P
Txt missing or int12v I/p to oin 2 PL1204 on txt pcb low at 10.5v; R761 1R = 5R
HitachiG6P
Txt lines at top of picIC681 µPC1378H
HitachiG6P
TRIPS HT COECT AT 110v IC501 PIN 24 ( START UC1101 ( MICRO RESET ) US
HitachiG6P
Tripping effect - line drive pulsingCheck C1101 2µ2
HitachiG6P
Sync poor or non existantC701 100µ 25v
HitachiG6P
Sound poor & intIC201 HA11485NT in IF unit dry joints
HitachiG6P
Sound level variesStab 12v line varies - ZD791 HZ11LC2 in Q791 base cct
HitachiG6P
SNOW ON SCREEN NO OSDIC1101 MICRO IC
HitachiG6P
Shutdown - after couple of seconds.ZD752 ( 24v zener ) leaky.
HitachiG6P
Shut down aft a couple of secs of sw onCrowbar thyristor Q902 firing - ok if gate dis'd - ZD752 24v in EHT sensing leaky


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.