Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Hitachi | G6P | Int cuts out after trying to start | 2D752 24v zener | ||
Hitachi | G6P | Green flashing pic with green fingers reaching out from left | Caption/on screen display gen chip IC1104 M50450-023P | ||
Hitachi | G6P | GREEN FLASHES ON PICTURE | REPLACE OSD ID | ||
Hitachi | G6P | Going to standby at switch on. | R902/3 ( 82k ) high. | ||
Hitachi | G6P | GOES STRAIGHT TO STBY | R902 903 82k HIGH OR OC | ||
Hitachi | G6P | Field top foldover | C682 100µ 50v | ||
Hitachi | G6P | Field cramp | C682 100µ 50v | ||
Hitachi | G6P | Fail to start up - int | Dry joint R1172 1k between pin 38 of micro & Q1103 coll | ||
Hitachi | G6P | Excess brill with fb lines | ZD301 12v leaky across lum feed to crt panel | ||
Hitachi | G6P | Dead, st/by LED OK, HT at 40v on dummy load | C914 1000µ 16v | ||
Hitachi | G6P | Dead without whistle | D902 ES1A s/c in psu | ||
Hitachi | G6P | Dead with whine | HT low at 50v on dummy load - LOPTx s/c winding | ||
Hitachi | G6P | DEAD LINE TR READS SC OR LOW B-E ( Q901 ) | CP901 HM9205 SC PINS 5 , 6 | ||
Hitachi | G6P | Dead after dying whine at sw on | dry joints line driver tfmr T721 lands | ||
Hitachi | G6P | Dead - momentary crack from spkr & led briefly flashes | OK on dummy load - LOPTx faulty |