Dicas Reparação ITT




Modelo - Chassis


Pesquisa: ITT Enviar Dica Resolvida
Resultados 517
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
ITTCVC1100
Dead - fuse Si651 Blown.D658 ( ZPY120 ) s/c. ( over-voltage protection )
ITTCVC1100
dead1A fuse o/c; BU536 s/c; D658 120v zener s/c; T713 BC328-25 leaky b-e
ITTCVC1100
Brightness low / over scanned after new LOPTXThe LOPTX just fitted is faulty!
ITTCVC1100
Blank raster & flyback lines int.Crack in print from 12v reg on stand up side panel.
ITTCVC100
dead with whistling only from psuNo 115v HT - 120v zener D658 leaky
ITTCTV1204 CVC1204
Dead.Blows BU508 at switch on , check C701 for s/c.
ITTCT600 CVC823
Line pulling - two or three times a second.VCR switch on PB unit.
ITTCT600 80R
Line pulling or jitter intermittent.Pk on video button - check VCR switch for grease on pins
ITTCT3835 Comp 80
Going into standby after a few minutes.C703 ( 10u f , 50v ) little blue one.
ITTCT3835
NO PICTURE RASTER OKT401 BC548 OC ( NO SANDCASTLE PULSES )
ITTCT3725/1 80R
Stuck in standby - with a noise from LTB.D732 ( BY500-400 ) s/c can use a RGP30
ITTCT3537
Int deadIC405 5v reg
ITTCT3437 Comp B
No startup just a low single thud.LOPTX D050/37 TFAT 3806
ITTCT3436 Trimline
Brightness at maximum.T1412 ( BC546 )
ITTCT3435
St/by onlyLOPTx - LOT192 Grandata u/s


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.