Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | K40 | BU508 LOP SC. , POWER SUPPLY WHISTLING , OVERVOLTAG | CNX62 OPTOCOUPLER | ||
Philips | K40 | Bright pic on LH side with vert lines | C2124 15µ 40v in IF can | ||
Philips | K40 | Blowing line transistor. | C2161/2163 , drys on line drive transformer. | ||
Philips | K40 | Blank screen - sound ok (Field collapse) | 3186 1R5 o/c, 2171/2175 1µ 63v caps (rh edge of sigs pcb) | ||
Philips | K40 | BLANK RASTER PIN 16 TDA2541 LOW ( NOT 5.2v ) OR PI | IF PIN 16 LOW C2115 IF 1 LOW CAPACITOR ON PIN 2 22nF | ||
Philips | K40 | Blank raster - no sound or vision. | C2115 ( 33nf ) leaky. | ||
Philips | K35 | Tuning - drifting with horizontal white bars. | D90 ( BA221 ) | ||
Philips | K35 | Slow warm up - dark picture. | C583 ( 4.7u f , 250v ) decouples 115v supply to RGB o/p. | ||
Philips | K35 | Remote - intermittent. | D32 leaky. | ||
Philips | K35 | No remote control. | Check for dirty contact on IC1 holder pin 13. | ||
Philips | K35 | NO FIELD | R590 O.C. , C521 S.C. 1.2ohms AND 1500mfd 25v | ||
Philips | K35 | LOSES MEMORY AT SWITCH OFF | CHECK POWER SUB PANEL BOTTOM OF CABINET. | ||
Philips | K35 | HT comes up then shuts down - E1 in display | Drys on Con LTB. | ||
Philips | K35 | GO INTO STANDBY IF TAPPED | CHECK THERMISTOR | ||
Philips | K35 | EW BOWING | 5R ON COLL OF TS490 OPEN |