PhilipsK40BU508 LOP SC. , POWER SUPPLY WHISTLING , OVERVOLTAGCNX62 OPTOCOUPLER
PhilipsK40Bright pic on LH side with vert linesC2124 15µ 40v in IF can
PhilipsK40Blowing line transistor.C2161/2163 , drys on line drive transformer.
PhilipsK40Blank screen - sound ok (Field collapse)3186 1R5 o/c, 2171/2175 1µ 63v caps (rh edge of sigs pcb)
PhilipsK40BLANK RASTER PIN 16 TDA2541 LOW ( NOT 5.2v ) OR PIIF PIN 16 LOW C2115 IF 1 LOW CAPACITOR ON PIN 2 22nF
PhilipsK40Blank raster - no sound or vision.C2115 ( 33nf ) leaky.
PhilipsK35Tuning - drifting with horizontal white bars.D90 ( BA221 )
PhilipsK35Slow warm up - dark picture.C583 ( 4.7u f , 250v ) decouples 115v supply to RGB o/p.
PhilipsK35Remote - intermittent.D32 leaky.
PhilipsK35No remote control.Check for dirty contact on IC1 holder pin 13.
PhilipsK35NO FIELDR590 O.C. , C521 S.C. 1.2ohms AND 1500mfd 25v
PhilipsK35LOSES MEMORY AT SWITCH OFFCHECK POWER SUB PANEL BOTTOM OF CABINET.
PhilipsK35HT comes up then shuts down - E1 in displayDrys on Con LTB.
PhilipsK35GO INTO STANDBY IF TAPPEDCHECK THERMISTOR
PhilipsK35EW BOWING5R ON COLL OF TS490 OPEN



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.