Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsGRl-AXIntermittently deadThe cause of this nasty fault turned out to be a small coil , L5524 , which filters the supply to the line driver stage. It was
PhilipsGR90AENO RED IN RGB INPUTBAS32 S.MOUNT DIODE D6854
PhilipsGR2-4Faint trippingC2550 680n 250v leaky
PhilipsGR21AAEHT BUT NO SOUND OR PIC AND A FLASHING LED ( WHENTDA2579B PRODUCING WRONG S.CASTLE PULSES
PhilipsGR21AADEAD WITH POWER SUPP. RUNNINGCHECK IC7880 PCA84C81AP/098 ( UNPLUG TEXT PCB TO PROVE )
PhilipsGR21AADEAD STBY LIGHT FLASHING NO LINE DRIVER3455 1k HIGH
PhilipsGR20 GR1AXLines at top of screenCoil 5524 reading 7R5
PhilipsGR2.4AAScreen went green & blinked outR3374/3434 1k5 o/c, R3431 180R, R3372 270R o/c, Tr7364 BF422 leaky on crt base. Caused by leakage in crt cured by rejuvenation
PhilipsGR2.4AANo raster - sound & EHT OK - loptr overheatsScan coils s/c due to dry joints on small pcb on scan coils
PhilipsGR2.4AADead with hissing/cracklingdry joints scan coil plug
PhilipsGR2.4AADead set with beep beep from psuDis plug M71 & check for 150v at coil L5631. If ok check LOP stage - LOPTr, LOPTx, F1534 o/c fuse, 6546 BY226 leaky (will have damaged diodes 6560 LL4148) & 6561 BZX79C68)
PhilipsGR2.4AADead - dry joints scan coil panelAlso damaged -1534 315mA fusible, 3570 6R8 resistor, 6560 LL4148 diode, 6561 BZX79-C68 zener & 7545 BU508AF LOPTr
PhilipsGR2.4 29PT727BTripping with burning smell possibleTr7545 LOPTr s/c due to C2550 dry joint &/or o/c
PhilipsGR2.4 29PT632ANo R/C functs after replacement of mains sw sub panelCheck for s/c track on o/p of IR rx
PhilipsGR2.4 29PT632ADead with burn up of mains sw & sub pcbReplacement pcb available from SEME



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads