PhilipsGR2.2BUT12AF keeps blowing every so oftenCheck mains res cap 220µ 385v for loose rivets
PhilipsGR2.2Black picture with unsynchronised teletext barsMeasure on pin 47 IC7800 (SAA5246); if period time is smaller then 1 micro second, replace crystal 1800 (4822 242 81191).
PhilipsGR2.2Black picture in teletext modeMeasure on pin 8 IC7800(SAA5246): if the DC voltage of the videosignal is not 1,8 Volt, then replace IC7800 (4822 209 31214).
PhilipsGR2.2Bad vertical linearity for 110 degree CRT.A. For mini/narrow neck and black line sets:R3506 becomes 130K (4822 116 52242) B. For black matrix sets: R3506 becomes 150K (4822 116 52245) C2506 becomes 680uF (4822 124 80063) R3471 becomes 75K (4822 116 52301) C.All sets: C2509 becomes 1uF (482
PhilipsGR2.2Bad synchronisation. Sometimes black picture.Pulses on pin 12 of IC7470 (TDA2579) is too low (3Vpp) because resistor R3539 is defective. 90° CRT 430K (4822 053 20434 ) Others 680K (4822 053 20684)
PhilipsGR2.2Bad sound.Delete 3237 in black matrix mono sets.
PhilipsGR2.2Bad sensitivity on remote control signalsReplace pos.nr 1003 by 4822 130 83821 (improved infra-red receiver)
PhilipsGR2.2Bad focus or picture shuts off with flyback lines in BL-S tubeCreate artificial flash-over in the CRT, by short circuiting Vg2 and focus and connect them for a short moment to aquadag.
PhilipsGR2.2ALWAYS COMES ON IN STBY AND CAN ONLY BE TURNED ONCHILD LOCK IN SPECIAL FUNCTIONS MENU IS TURNED ON
PhilipsGR2.2After some time power-supply shuts off.Check diode D6612 (1N4148) after warming up. Protection pin 8 IC7600 is about 2V, diode D6666 is leaking. Check D6666 (4822 130 80887) (UZ-C36 in case of 25" and 28") (4822 130 81141) (UZ-C43 in case of 21")
PhilipsGR2.2Adjustment of white balance is difficult in black matrix CRTReplace position number 3382, (3K9) on CRT panel by 4K3 (4822 051 10432) REMARKS : Typenumbers with CRT-Panel on CRTs A59EAK220X13, A59EAK71X03, A66EAK220X13
PhilipsGR2.2Adaptation in productionAdaptation in production Replace BZT03-C16 on pos. nr. 6611 on main panel by BZV85-C16
PhilipsGR2.2"S" in screen, cannot go from service mode.Diode 6705 (BZV55-F5V1; 4822 130 80905) leaks.
PhilipsGR2.1ABThump from spkr then tripsDis'd TDA2613 audio o/p chip brought back pic but replacement along with R3241 8R2 failed to cure; soft start cct faulty - T7247 BC848 s/c
PhilipsGR2.1ABRaster present with green LED flashingHT was low when connected to LOP but ok on bulb - Audio o/p chip was s/c



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.