Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsGR2.1Distorted picture during high contrast scenes (picture breathing)A production change has been applied to the east/west circuit to maintain the picture shape during scenes with high contrast transients, i.e. between sky and earth. Position Old New Code number R3526 82K(100K) 47K
PhilipsGR2.1Dark screen, LED blinksIf the LED obeys RC, uP is OK. Fault in power supply or TDA4680 (IC7309; 4822 209 63733). The problem occurs in sets produced in the beginning of the series. There is no problem if the software is MR5.
PhilipsGR2.1Crackling noise in left loudspeaker.When after replacing R3207 (R3214 for nicam) by a special version code 4822 116 83726 you still hear the cracking noise it can be helpful to resolder the 6 components of the amplifier stage arround 7232 (7217 for nicam).
PhilipsGR2.1Changing option codes.It has been discovered that changing the option code for nicam (from ON to OFF or vice versa) will not effect this change. If this problem occurs, the option code can be changed as follows: Change option code for nicam as requested. Change option code fo
PhilipsGR2.1Buzz on sound in mono sets onlyThe buzz on sound on VCR playback can be reduced by replacing the sound quadrature coil 5035 on the sound IF module. (4822 157 63077). Realign the new coil for optimum sound quality.
PhilipsGR2.1Black picture with unsynchronised teletext barsMeasure on pin 47 IC7800 (SAA5246); if period time is smaller then 1 micro second, replace crystal 1800 (4822 242 81191).
PhilipsGR2.1Bended horizontal lines at top and bottom of the pictureMount correctionmodule 4822 212 31384 (seagull), and do the alignments on this module.
PhilipsGR2.1Bad search tuning GR2.1 mono versions on local cable nets.Add on the monocarrier between junction R3714/R3735 and earth an electrolitic capacitor 1 uF/16V (4822 124 40242) mount the capacitor on the location of the reserved item number 2707. The problem has been observed on local cable nets special on the lower
PhilipsGR2.1"S" in screen, cannot go from service mode.Diode 6705 (BZV55; 4822 130 80914) leaks.
PhilipsGR2 24ST1724Excess width after replacement of faulty LOPTr & line dr chip TDA2579R3565 15R o/c - safety res in -26v supply
PhilipsGR2narrow pic - e/w faultdry joints TR7533 E/W mod driver - tr7530 BC848 faulty
PhilipsGR2Int shutdown & poor response to R/C & OSD corruptedCNR50
PhilipsGR2INT SHUTDOWNCNR50 POWER CONTROL IC
PhilipsGR1AX chassisArcing sounds on startup.Change Capacitor 2523 6,8uF
PhilipsGR1AX chassisArcing sounds on startup.Change Capacitor 2523 6,8uF



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.