PhilipsGR1AXRepeat failure of line output transistor item 7528After fitting a new transistor Type 2SC3795B Pt. No.4822 130 60676 check soldered connections to socket M3
PhilipsGR1AXRepair-tip power-supplyRepair-tip power-supply ----------------------- It is not allowed to connect a measuring probe to the gate of MOS-FET transistors TS7610 because the set will not function well, or the MOS-FET might be damaged.
PhilipsGR1AXReluctant start from cold - no 95v HTOK if set HT pot reduced - Zener 6638 BZX79-B36 in HT sensing leaky
PhilipsGR1AXPrograms and PP-settings cannot be changedIt may happen that when switching on from standby the set comes on in "store lock" mode (sometimes called "hotel mode"). In this mode stored settings for programme selection and personal preference cannot be changed (see operating instructions for leavin
PhilipsGR1AXProgramme tuning difficulty, stations shifted on the tuning bar.Stations appearing to the right of the usual position on the tuning bar although the bar itself scans normally. Higher channels may not be accesssible at all. Investigation has shown that although the 33V supply and the pulse drive from pin 1 of IC7700
PhilipsGR1AXProduction change to line driveProduction change to line drive ------------------------------- A production change has been introduced to the line drive circuit. Receivers affected are factory coded SV008921 and higher. Reason: To improve the function of the line drive circuit. Pos
PhilipsGR1AXProduction change to +9V supplyProduction change to +9V supply ------------------------------- A production change has been introduced to the +9 volt supply. Receivers concerned are factory coded SV008921 and higher. Position Old New Code No. 3100
PhilipsGR1AXPower supply tripping.95 volt line pulsing. Check/replace R3614 - 6.8k (4822 053 11682) in chopper driver coupling circuit.
PhilipsGR1AXPower supply not working.Check D6610 for short-circuit (BZX79-C10; 4822 130 61219).
PhilipsGR1AXPower supply faultfindingPower supply faultfinding ------------------------- The power supply in the GR1-AX delivers approximately 33 watts on the +95V line to run the set. Clearly the practice of using a 60 watt 240V lamp as a load during fault finding cannot be applied in this
PhilipsGR1AXPower supply does not oscillate.Check C2613 (33nF; 4822 121 42489) on leakage.
PhilipsGR1AXPoor reproduction of copy protected tapesIt is possible that reproduction of some VCR tapes will be adversely affected by anti copy signals which are recorded on the video tape during the sync. period. A significant improvement can be achieved by applying the following modification: Position
PhilipsGR1AXpoor line syncC2501 ( 10uF )
PhilipsGR1AXPoor H.T regulation and intermittent over voltage tripping.D6629 (BZX79-B6V2; 4822 130 34167).
PhilipsGR1AXPicture fails for a short time.Diode 6542 (BYD33D) dry joint.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.