Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | GR1AX | Hotel mode (de)activation for GR1AX with 3 local c | Hotel mode (de)activation for GR1AX with 3 local controls --------------------------------------------------------- Only for sets with 3 local controls In service information HOTEL MODE for GR1AX / Anubis A&B / TV/VCR-1 4822 727 20384 a mistake is made f | ||
Philips | GR1AX | Hotel mode | Hotel mode ---------- Control microprocessors are available for these chassis with or without the "hotel" mode feature. Original production included "hotel" mode but the feature was deleted to reduce the number of "nuisance" service calls generated by mi | ||
Philips | GR1AX | Half a pic - line wrap around | line sect of scastle pulse at R3529 missing to IC7020 TDA8305 - crack in print at corner of pcb | ||
Philips | GR1AX | H.T. varies sound goes up to Max | C2631 ( 22nF ) | ||
Philips | GR1AX | H.T. high | R3562 ( 33K ) | ||
Philips | GR1AX | Green picture | Check T7435 (BF422; 4822 130 41782) on the CRT panel. | ||
Philips | GR1AX | Green pic with fb lines &/or no tuning/chan change | TMP47C434-3559 micro | ||
Philips | GR1AX | GR1AX with 8 local controls with uC TMP47C634N-R49 | GR1AX with 8 local controls with uC TMP47C634N-R494 (for sets with SV-codes) ------------------------------------------------------------------ 4822 209 31641 Hotel mode for uC TMP47C634N-R494: YES Hotel mode activation for uC TMP47C634N-R49 | ||
Philips | GR1AX | GR1AX with 8 local controls with uC TMP47C434N-R22 | GR1AX with 8 local controls with uC TMP47C434N-R221 --------------------------------------------------- 4822 209 32192 Hotel mode for uC TMP47C434N-R221: YES Hotel mode activation for uC TMP47C434N-R221: 1. Select program 38 2. Press | ||
Philips | GR1AX | GR1AX with 8 local controls with uC TMP47C434N-353 | GR1AX with 8 local controls with uC TMP47C434N-3537 --------------------------------------------------- Replaced by uC TMP47C434N-R221; 4822 209 32192 Hotel mode for uC TMP47C434N-3537: NO | ||
Philips | GR1AX | GR1AX with 8 local controls with uC TMP47C434N-341 | GR1AX with 8 local controls with uC TMP47C434N-3415 --------------------------------------------------- Replaced by uC TMP47C434N-R221; 4822 209 32192 Hotel mode for uC TMP47C434N-3415: YES Hotel mode activation for uC TMP47C434N-3415: 1. | ||
Philips | GR1AX | GR1AX with 3 local controls with uC TMP47C434N-314 | GR1AX with 3 local controls with uC TMP47C434N-3141 --------------------------------------------------- Replaced by uC TMP47C434N-3142; 4822 209 32118 Hotel mode for uC TMP47C434N-3141: NO | ||
Philips | GR1AX | GR1AX with 3 local controls with uC TMP47C434N-314 | GR1AX with 3 local controls with uC TMP47C434N-3142 --------------------------------------------------- 4822 209 32118 Hotel mode for uC TMP47C434N-3142: YES Hotel mode activation for uC TMP47C434N-3142: 1. Select program 38 2. Press | ||
Philips | GR1AX | Field non lin with line thro centre | R3506 13k or 43k hi res | ||
Philips | GR1AX | Field collapse usually with blank screen | IC7500 ( TDA3653 ) |