PhilipsGR1AXDead with HT only 1.5v & PSU whistlesReplace 6641 SF2D41 protection thyristor
PhilipsGR1AXDead with burning smellBUT11AF lop tr & dry joints scan coil connector etc
PhilipsGR1AXDead set - psu OKMicro not working but replacement didn't cure - unplug Txt panel got set working - IC7880 PCA84C81AP/098 u/s
PhilipsGR1AXDEAD LOP TRANSISTOR SC REPLACEMENT BLOWS AFTER 5miL5519 ( LINE DRIVE ) OR LOPTX
PhilipsGR1AXDEAD 95v RAIL AT 5vD6671 4v3 US
PhilipsGR1AXDEAD , NO LINE OSC.Check C2519 ( 150pF ) pin 26 TDA8305 Check D6030 12v ZENER & D6523
PhilipsGR1AXDead - tripped due to high HTR3610 330k in psu hi res
PhilipsGR1AXDead - psu shutdowns/c between pins 1 & 6 of Loptx - replaced
PhilipsGR1AXDead - psu not starting HT = 15vD6613 15v zener - checked ok out of cct
PhilipsGR1AXDead - pri HT onlyLoptx o/c winding 1/5
PhilipsGR1AXDead - no line oscD6030 12v zener o/c
PhilipsGR1AXDead - no 95v from PSU.D6638 ( BZX79-B36 ) s/c.
PhilipsGR1AXDead - low o/p from psuR3610 & R3613 faulty - caused by D6610 zener in FET gate faulty
PhilipsGR1AXDead - LOPTr s/c & replacement lasted 5 minsLine drive wfm dist - L5519 3µ3 in series with o/p from line timebase chip shorted turns
PhilipsGR1AXDead - HT ok - no lop activityL5224 supply to line dr discoloured & o/c



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.