Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsG90AEWeak video & no syncTDA5850
PhilipsG90AETxt poor - looks like purity errorsDry joints wire links on main pcb near Txt panel
PhilipsG90AETXT horizontal synchronization missingCheck horizontal phase discriminator detection filter capacitor C2827 (47nF; 4822 122 32542).
PhilipsG90AETuning, display and remote control not functioningVoltage of pin 42-IC7720 low, TR7661 defective (BD135; 4822 130 40823).
PhilipsG90AETuning unstableVoltage on diode D 6770 not stable Replace D 6770 (ZTK 33B; 4822 130 30959)
PhilipsG90AETrips rapidlyTr7652 BC557C in pulse width mod in psu
PhilipsG90AETrips on & off violently aft several minsOzone smell - focus pin arcing - replace crt base
PhilipsG90AETripping with clcking thro spkrSame on dummy load - Replace C2630/1 47µ 160v. R3668 sm 150R had dropped off. Replaced also 7652 BC557C & opto coupler as precaution
PhilipsG90AETripping aft 10 mins operationCan be instigated by heating/cooling around psu - replaced 150R sm (R3668?)
PhilipsG90AETrippingIf HT set at 95v tripping stops but blank raster. Xtal filter 1030 s/c with solder
PhilipsG90AEThe voltage of +95V line altersCheck transistor 7653 (BC858A; 5322 130 42012).
PhilipsG90AEThe upper part of picture consists of few linesCheck C2475 (33nF/63V; 5322 122 31848).
PhilipsG90AESwitches off and on shortlySelects always program 1 and adjusts PP-value.Check C2397 (33nF; 5322 121 41763) on the CRT panel for leakage. Bend C2397 on picture-tube PCB from picture-tube socket.
PhilipsG90AEStuck on chan 8, front controls & R/C inop - st/by led flashingReplace C2843 [220uf] in 5 volt regulator
PhilipsG90AEStriationsA production change has been introduced adding the following components in the +95 volt feed to the line output stage: Description: Position no. 5558 Code no. 4822 158 10563 Choke 82uH Capacitor 10n 100V Position



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads