PhilipsG90AERagged vertsC2630 47µ HT res cap leaky
PhilipsG90AERagged verticals on some pictures.C2630 ( 47uF ) HT reservoir con.
PhilipsG90AERagged pic, dim displayC2640 680µ 22v smoother, C2580 470µ 12v smoother
PhilipsG90AEPulsing/rolling/jagged white line at top of screenIC7470 TDA2579 timebase chip
PhilipsG90AEPSU pulsing with LED flashing in timeHT o/p only 80/90v when LOP dis'd (should be 95v) - check soldering of sm comps on psu sec
PhilipsG90AEPower supply failureIn the event of a failure in the switch-mode power supply, the switching transistor IC7625 may have failed. In this case it is recommended that the opto-coupler IC7614 should also be replaced. 7625: BUT11AF; 4822 130 42679 7614: CNX83A; 4822 130 82034
PhilipsG90AEPopping from spkrs only at sw onC2630/31 smoothing caps 47µ 250v
PhilipsG90AEPoor contrast rangeC2560 33nF leaky in beam current limiter cct
PhilipsG90AEPicture too darkVoltage on pin 7 S 5545 (line transformer) < 3,2V Replace C 2560 (33 nF; 4822 121 51385).
PhilipsG90AEPicture becomes dark from time to time, cannot be adjustedTransistor 7869 (PMBT2369; 4822 209 73852) base not soldered.
PhilipsG90AEPic goes dark aft 2hrs & no chan change Display shows F4IC7720 faulty
PhilipsG90AEOver-voltage circuit activeDisconnect connector A5 and connect a bulb to +95 Volt. Bulb burns. Check/replace TS7545 (BUT11AF;4822 130 42679) and S5545 (line transformer; 4822 1040 10306)
PhilipsG90AEOscillation wide in weak field on the right side.It moves to the left and disappears after the set has warmed. Check/replace transistor 7533 (BC636; 4822 130 44283) in east-west circuit.
PhilipsG90AENo vertical deflectionNo vertical control signal on pin 1 IC 7470 Replace IC 7470 (TDA 2579/N6; 4822 209 72363) Replace D 6465 (BAS 32L; 4822 130 80446)
PhilipsG90AENo Txt & "F7" in display with sound possibly missingC2843 220µ



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.