Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsG90TrippingR3668 sm 150R
PhilipsG90snowy piccheck pin 6 tuner. If absent check R3001 15R
PhilipsG90SET WORKS BUT NO TEXT AND F7 DISPLAYED ON SCREENNO RESET PULSE TO IC7800 CHECK TR7846 AND C2843 220uF
PhilipsG90Picture too bigReplace T7652 & CNX83 opto
PhilipsG90off with s/by led flashinght low & pulsing - R3632 15k in prot cct u/s - C2630 & R3668 also possible
PhilipsG90no start up - trippingD6611, 6613, 6614 BAS32
PhilipsG90NO LINE OSCIF VOLTAGE ON PIN 16 TDA2579 IF NOT 9v CHECK ACROSS D6455 5v6 ZENER IF OK HERE REPLACE T7455 IF NOT REPLACE ZENER
PhilipsG90No blue.D6416 ( BAS32 ) leaky.
PhilipsG90Int loss of tuningX2402 eeprom chip
PhilipsG90Frame collapse.Wickman fuse to o/p transis o/c , R3503/07 , R3501 390k o/c.
PhilipsG90field collapseD6465 sm
PhilipsG90Dead.Check for drys on chip diodes.
PhilipsG90Dead chopper transistor s/c.Also change CNX83A optocoupler part No.4822 130 82034
PhilipsG90CONTRAST CONTROL LIMITEDC2560 ( 33nf ) LEAKY PIN 7 , LOPT.
PhilipsG90Continuous page header display in subtitleChange text IC to type MAB8461P/W196 part No4822 209 62479



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.