Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | G110-PTV | Preventive action | Preventive action . After replacing a projection tube, the deflection coil may shift downwards. To keep the deflection coil on its correct location, the coil should be glued to the new projection tube. Adhesive 4822 390 30066 should be applied between t | ||
Philips | G110-PTV | Horizontal adjustment does not work. Picture too wide. | Elco 2549 (10uF) capacity reduced. Replace by code 4822 124 80275 (mechanically bigger). | ||
Philips | G110-PTV | Excessive width | In the case of excessive width, it is possible that C2549 (east/west circuit) is low capacity. To improve reliability an alternative type of capacitor should be used as a replacement. However, the dimensions of this capacitor are different from the origi | ||
Philips | G110-PTV | Excess width | C2549 10µ 50v in EW Corr cct | ||
Philips | G110-PTV | Addition to parts list | Addition to parts list. The EHT cable CRT to splitter (3) is available under code number 4822 320 20192. Please add to the parts list in the G110 PTV chassis service manual. | ||
Philips | G110 25GR9762 | Int blows wickman fuse 1534 esp when chassis in place | Dry joints pin 2 E/W Tx | ||
Philips | G110 25GR9762 | Blows Wickman fuse 1534 int | Dry joint pin 2 E/W Trfmr | ||
Philips | G110 25GR9660/22B | Width excessive | Pot 3525 10k o/c | ||
Philips | G110 25GR9660/22B | No horizontal adj | pot 3595 1K o/c, 2593-2594 caps both 10uF 63V leaky, resistor 3596 150R o/c & res 3502 8k2 heat stressed | ||
Philips | G110 25GR5764?05B | Pic randomly disappears with no Txt - only lines | Fault on Txt panel - could be coil L5803 which is unavailable or remove Txt pcb so that the TV works minus Txt | ||
Philips | G110 | Won't start up - P.S squeals. Voltages lower than normal. | Sound IC defective. After replacement, PS protection active- Change also 7281&7282(BC848) near sound IC | ||
Philips | G110 | Won't start up - P.S squeals. Voltages lower than normal. | Sound IC defective. After replacement, PS protection active- Change also 7281&7282(BC848) near sound IC | ||
Philips | G110 | Wont power up unless pin 3 LOPTx dis'd | This is the 14v supply which feeds 12v reg. Q7284 BC858 sm in audio prot stage was leaky | ||
Philips | G110 | Will not start; +148V = +/- 20 volts | Fault suspected in Line output stage. Disconnect pin 3 of LOT transformer. If +148V comes to normal and line drive is achieved; reconnect pin 3 of LOT and try disconnecting R3281 (location D4 of PCB). If set starts up, suspect T7284 audio protection tra | ||
Philips | G110 | Width excessive & varies with brightness | C2526 6n8 sm cap in EW mod cct leaky |