SintomaCausaSoluçãoPor:
PhilipsG110-PTVPreventive actionPreventive action . After replacing a projection tube, the deflection coil may shift downwards. To keep the deflection coil on its correct location, the coil should be glued to the new projection tube. Adhesive 4822 390 30066 should be applied between t
PhilipsG110-PTVHorizontal adjustment does not work. Picture too wide.Elco 2549 (10uF) capacity reduced. Replace by code 4822 124 80275 (mechanically bigger).
PhilipsG110-PTVExcessive widthIn the case of excessive width, it is possible that C2549 (east/west circuit) is low capacity. To improve reliability an alternative type of capacitor should be used as a replacement. However, the dimensions of this capacitor are different from the origi
PhilipsG110-PTVExcess widthC2549 10µ 50v in EW Corr cct
PhilipsG110-PTVAddition to parts listAddition to parts list. The EHT cable CRT to splitter (3) is available under code number 4822 320 20192. Please add to the parts list in the G110 PTV chassis service manual.
PhilipsG110 25GR9762Int blows wickman fuse 1534 esp when chassis in placeDry joints pin 2 E/W Tx
PhilipsG110 25GR9762Blows Wickman fuse 1534 intDry joint pin 2 E/W Trfmr
PhilipsG110 25GR9660/22BWidth excessivePot 3525 10k o/c
PhilipsG110 25GR9660/22BNo horizontal adjpot 3595 1K o/c, 2593-2594 caps both 10uF 63V leaky, resistor 3596 150R o/c & res 3502 8k2 heat stressed
PhilipsG110 25GR5764?05BPic randomly disappears with no Txt - only linesFault on Txt panel - could be coil L5803 which is unavailable or remove Txt pcb so that the TV works minus Txt
PhilipsG110Won't start up - P.S squeals. Voltages lower than normal.Sound IC defective. After replacement, PS protection active- Change also 7281&7282(BC848) near sound IC
PhilipsG110Won't start up - P.S squeals. Voltages lower than normal.Sound IC defective. After replacement, PS protection active- Change also 7281&7282(BC848) near sound IC
PhilipsG110Wont power up unless pin 3 LOPTx dis'dThis is the 14v supply which feeds 12v reg. Q7284 BC858 sm in audio prot stage was leaky
PhilipsG110Will not start; +148V = +/- 20 voltsFault suspected in Line output stage. Disconnect pin 3 of LOT transformer. If +148V comes to normal and line drive is achieved; reconnect pin 3 of LOT and try disconnecting R3281 (location D4 of PCB). If set starts up, suspect T7284 audio protection tra
PhilipsG110Width excessive & varies with brightnessC2526 6n8 sm cap in EW mod cct leaky



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.