Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | G110 | Red flashing when changing chs using VCR. | Mod see Tv Mag. | ||
Philips | G110 | Protection of T7625 (BUT18AF) | Protection of T7625 (BUT18AF) A production change is being introduced adding two diodes connected in series between the base and emitter of TS7625 (anodes towards base). The type no. for the diodes is BYD73B service code no. 4822 130 60778 Reason: To i | ||
Philips | G110 | Poor width reg with brightness (HT constant) | sm C2526 8n2 leaky | ||
Philips | G110 | POOR SOUND ON LH SPEAKER ON NICAM ONLY | IC7530 + IC7531 LM833 ( ONE LH ONE RH ) | ||
Philips | G110 | Poor in contrast. | Replace T7413 on the picture tube PCB (BC856B; 4822 130 60373). | ||
Philips | G110 | Picture twists from top | Voltage of pin 8-IC7450 (TDA3654Q) on the LSP has raised to ca. 20 V. Check diode 6451 (BZX79/C5V6; 4822 130 80954). | ||
Philips | G110 | Picture moved and a black bar in the middle of the screen | Tinbridge over C2460. Pin 12 in TDA2579 leaks. | ||
Philips | G110 | Picture distorted | Vertical pulse incorrect. Check capacitor C2500 (220 pF; 4822 122 31965). | ||
Philips | G110 | Pic shifted & black line down centre of screen | TDA2579 pin 12 has leak to chassis due to solder bridge | ||
Philips | G110 | Page 811 appears spontanuously | Decoder selects page 811 and blocks Mount new uP (IC 7800) MAB 8461P/W196 (4822 209 62479) on TXT-Decoder. | ||
Philips | G110 | OSD partly disappeared from the screen in BL sets. | Modify C2758 and C2702 from 12pF into 10pF (4822 122 31971). | ||
Philips | G110 | One inch black band down lh side of screen | Tr7594 BC848 & Tr7593 BC858 sm s/c | ||
Philips | G110 | off | if low res across lop tr (<1k) check lop tr lopt C2550, C2545 1n2 2kv | ||
Philips | G110 | off | ok when s/c prot line - D6657 (LLZ-C20) 16v supply monitor | ||
Philips | G110 | Noise in picture | IC7425 (TDA4565; 4822 209 71512) defective. |