Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | G110 | At times no synchronization. | Check capacitor C2366 (100 nF; 4822 122 33496). | ||
Philips | G110 | At times no picture. | Check C2366 (100 nF; 4822 122 33496). | ||
Philips | G11 | Width - lack of width on bright picture. | C3105 ( 0.0022uf ) | ||
Philips | G11 | Width - control will not set correct. | D3132. | ||
Philips | G11 | Tuning - drift after period of time. | IC TAA550. | ||
Philips | G11 | Tripping - picture dark & no colour. | IC2510. | ||
Philips | G11 | Tripping - maybe intermittently. | LOPTX ( diode split ) | ||
Philips | G11 | Striations on left hand side. | Add ferrite bead to wire link between tag14 of LOPTX. | ||
Philips | G11 | Sound - volume control inoprative. | IC1 ( SAA5010 ) , R49 ( 10R ) | ||
Philips | G11 | Sound - no sound or picture EHT ok. | IC507 ( TDA1412 ) 12v reg. | ||
Philips | G11 | Sound - no sound & blank raster. | TR6462 ( BF196 ) . | ||
Philips | G11 | Shutdown - shuts down after a few seconds. | D4001 ( 7 5v ) zener leaky. | ||
Philips | G11 | Raster - bright with flyback lines. | Drys on line o/p panel , if text remove to isolate. | ||
Philips | G11 | Picture small. | Volts at F4037 down to 130v , D4048 ( zener ) | ||
Philips | G11 | Picture shifts certically. | IC2520 ( TDA2600 ) poor contact on T/B panel. |