Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsG11Picture shifted.Check for solder bridge under chip capacitor C2460
PhilipsG11Picture narrow.C3135 ( 0.91uf )
PhilipsG11Picture dark & no colour.IC2510.
PhilipsG11One colour missing.O/C print in control unit 1617.
PhilipsG11No startup from when cold.Line coupling capacitor C3110 dried up.
PhilipsG11No sound.Check pins/sockets 5C1 , 5C2 ( LT1 ) , 12v stabiliser.
PhilipsG11No remote control operation.Check no one has soldered the 3rd pair on contacts on Sw
PhilipsG11No picture.BU208 , LOPTX s/c , check screened lead from T/B to LOPT pcb
PhilipsG11No picture.BU208 s/c , check C4029 , C3135 ( 0.91uf )
PhilipsG11No picture or sound EHT ok.IC507 ( TDA1412 ) 12v reg.
PhilipsG11No picture - sound ok.0.91uf ( yellow ) on line TB panel.
PhilipsG11No picture - EHT ok.D4090 ( 4v7zener ) , D6011 , TR2164 ( BC148 )
PhilipsG11No luminance.4.7v zener in beam lim cct on PSU.
PhilipsG11No colour.C6062 , C6070 ( 0.33uf ) , alignment of L5630.
PhilipsG11No colour & dark picture.IC2510.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.