Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsG11Brightness - decreasing - loss of colour lockC3150 ( 150u f ) , C5067 ( 10u f ) , 12v reg chip IC5073 ( TDA1412 )
PhilipsG11Blowing - DA4600.Intermittent connections on holder , C4079.
PhilipsG11Blank raster & no sound.TR6462 ( BF196 ) .
PhilipsG11Black vertical bar in centre of picture.Check for solder bridge under chip capacitor C2460
PhilipsFL4.27Wrong synchronization, unstable colorsD6417 on the LSP dependent on temperature, check/replace (4822 130 81223)
PhilipsFL4.27Wrong service batch of ST24C08CB1 memory IC'sWrong service batch of ST24C08CB1 memory IC's 4822 209 32283 ------ Temporarily a wrong batch of EAROM's has been delivered, causing the fault "NVM MEMORY NOT WRITE PROTECTED" after replacing the EAROM
PhilipsFL4.27White picture and shuts of.No +200V on pin 6 IC7706 on picture tube panel. Resistance from pin 6 TDA611/Q to mass too low ( 15 Ohm.)
PhilipsFL4.27Unstable picture, horizontal jitter.Check/replace R3405 on the LSP. (4822 051 10303 for 50 Hz sets; 4822 051 10333 for 100 Hz sets).
PhilipsFL4.27Tuning does not functionResistor R3240 on LSP in V-tuning wire broken.
PhilipsFL4.27Total inoperative, leds blinking, error 99Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the Large signal panel. Replace by a 3kV15 HR-R capacitor if possible: 820pF 4822 126 13152 1nF 4822 126 13153 1,2nF 4822 126 13154 1,5nF 4822 126 13155 1,8nF 4822 126 13156 2,
PhilipsFL4.27Ticking noise and line in pictureTransistor 7381 (BC848C; 5322 130 42136) defective when hot.
PhilipsFL4.27Synchronization, picture disappearsD6703 and T7704 defective on picture tube panel.
PhilipsFL4.27Supply switch-off sometimesCheck the +5 stand-by. This voltage has to be 5.5V and may not vary. When the voltage drops below 5.2V the set switches-off. Cure: check leakage of D6266 (BZX79/F6V8; 4822 130 34278)
PhilipsFL4.27Supply +5V too low, black horizontal bar in picture. Bad sync.Check/replace IC7551 (LM358N; 4822 209 70672)
PhilipsFL4.27Spook in pictureUse special antenna cables. Codenumbers: 4822 321 61224 PAL 1 meter 4822 321 61225 PAL 2 meter 4822 321 61226 SECAM 1 meter 4822 321 61227 SECAM 2 meter



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads