Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | FL4.17 | Both languages can be heard by Dual Nicam signals | For FL1-PTV change the software into V89; 4822 900 10732 For all other FL sets change the software into V88; 4822 900 10723 REMARKS :Introduced in production from week 9614 onwards. | ||
Philips | FL4.17 | Blank picture. OSD not synchronised and too large, no TXT. | Check/replace memory IC 7900 (ST24C08CB1; 4822 209 32283). | ||
Philips | FL4.17 | Bad synchronization with external signals | Delete position 3115 on the ECO 100Hz box. REMARKS : Introduced in production in week 9415. | ||
Philips | FL4.17 | Bad picture. Picture scrolls. No RC reaction. | +5V was 4,1V instead of 5,1V. Replace IC7551 (LM358N; 4822 209 70672) | ||
Philips | FL4.17 | Bad pict. No menu. Dark bars over pict. Red pict. in dig.scan mode. | +5V was 4,3V instead of 5,1V. IC7551 (LM358N 4822 209 70672) defective. IC7209 (SAA7158 4822 209 31059) Bendic defective. | ||
Philips | FL4.17 | Bad focus or focus varies in a new set or after CRT replacement | Possible solution: Short circuit the focus and the G2 pins of the picture tube with the aquadag coating. Switch the set on for approximately 5 seconds. After this return the set to its original condition. Check if the focus adjusted normally. If not repla | ||
Philips | FL4.17 | Antenna input: no sound. External input: sound O.K. | Check whether crystal 1602 (stereo decoder) 10MHz oscillates. If not replace X1602 (4822 242 80276). | ||
Philips | FL4.17 | After 10 minutes picture becomes red from right side | C2395 on the LSP poorly soldered. | ||
Philips | FL4.17 | "NVM write protection enabled" message on screen. | Startup problem or 'NVM write protection enabled' message on screen after replacement of NVM (ST24C08CB1; 4822 209 32283) with a ST24C08CB6 (4822 209 33113). Use as replacement the ST24C08 1 (9311 021 36682). | ||
Philips | FL4.16 | Supply switch-off sometimes | Check the +5 stand-by. This voltage has to be 5.5V and may not vary. When the voltage drops below 5.2V the set switches-off. Cure: check leakage of D6266 (BZX79/F6V8; 4822 130 34278) | ||
Philips | FL4.16 | Supply +5V too low, black horizontal bar in picture. Bad sync. | Check/replace IC7551 (LM358N; 4822 209 70672) | ||
Philips | FL4.16 | Sound shuts off and OSD in picture. | Voltage on pin 4 TDA8417 was 3.5V tt instead of >4.5V TT. Replace X-tal 10 Mhz (4822 242 80276). | ||
Philips | FL4.16 | Sometimes vibration in vertical direction. | Replace C2410 (150nF 5%; 4822 121 41854) on LSP. | ||
Philips | FL4.16 | Sometimes in protection, or hor. width varies | Check or resolder on LSP the pins of E/W bridge coil 5521. | ||
Philips | FL4.16 | Shuts off and on again on Pr.nr. 1 after 3 hours. | D6272 (BZX55B5V6) interruption when it becomes hot. |