Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | FL2.14 | Total inoperative, leds blinking, error 99 | Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the Large signal panel. Replace by a 3kV15 HR-R capacitor if possible: 820pF 4822 126 13152 1nF 4822 126 13153 1,2nF 4822 126 13154 1,5nF 4822 126 13155 1,8nF 4822 126 13156 2, | ||
Philips | FL2.14 | Ticking noise and line in picture | Transistor 7381 (BC848C; 5322 130 42136) defective when hot. | ||
Philips | FL2.14 | Synchronization, picture disappears | D6703 and T7704 defective on picture tube panel. | ||
Philips | FL2.14 | Switching from mode 4x3 to 16x9, picture disappears when cold | Check IC7430 (TDA4680, 4822 209 31592). | ||
Philips | FL2.14 | Supply switch-off sometimes | Check the +5 stand-by. This voltage has to be 5.5V and may not vary. When the voltage drops below 5.2V the set switches-off. Cure: check D6266 for leackage (BZX79/F6V8; 4822 130 34278) or check T7268 for leackage (BD943F; 4822 130 62742). The 5.5V is meas | ||
Philips | FL2.14 | Supply +5V too low, black horizontal bar in picture. Bad sync. | Check/replace IC7551 (LM358N; 4822 209 70672) | ||
Philips | FL2.14 | Spook in picture | Use special antenna cables. Codenumbers: 4822 321 61224 PAL 1 meter 4822 321 61225 PAL 2 meter 4822 321 61226 SECAM 1 meter 4822 321 61227 SECAM 2 meter | ||
Philips | FL2.14 | Spoke on 134,25 and 287,25 MHz in proscan sets. | Spoke on above mentioned frequency can be solved by adding two capacitors of 33pF (5322 122 32072) on the LFR box. - between pin 10 of H22 and earth (pin 5 of H22) (CVBS). - between pin 7 of H21 and earth (pin 4 of H21) (TXT INT). | ||
Philips | FL2.14 | Spare part information | Spare part information ---------------------- New mainsswitch bracket FL2 sets. In week 9424 the bracket for the mainsswitch of the FL2 sets is changed from 4822 404 31286 into 4822 404 31415. It is not possible to use the new brackets (4822 404 31415) in | ||
Philips | FL2.14 | Sound shuts off and OSD in picture. | Voltage on pin 4 TDA8417 was 3.5V tt instead of >4.5V TT. Replace X-tal 10 Mhz (4822 242 80276). | ||
Philips | FL2.14 | Sometimes vibration in vertical direction. | Replace C2410 (150nF 5%; 4822 121 41854) on LSP. | ||
Philips | FL2.14 | Sometimes in protection, or hor. width varies | Check or resolder on LSP the pins of E/W bridge coil 5521. | ||
Philips | FL2.14 | Shuts off and on again on Pr.nr. 1 after 3 hours. | D6272 (BZX55B5V6) interruption when it becomes hot. | ||
Philips | FL2.14 | Set totally inoperative, no LEDs on. Supply hums. | R3252 220 kOhm (Start-up micro-sops) defective (4822 116 52258). | ||
Philips | FL2.14 | Set sometimes goes in STAND-BY and immediately switches ON again. | Replace position IC7120 on LFR box (PCF83C652P/AB/043) by P83C652FFP/50 V34D (4822 209 33289). REMARKS : Introduced in production in week 9337. |