Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | FL1.6 | Service manual correction option code 1 | Service manual correction option code 1 --------------------------------------- On the service (model) manual (4822 727 19142) of this type optioncode 1 is not correct. This has to be the following: 33ML8905/00B/02B/06B/08B: 154 33ML8905/05B: | ||
Philips | FL1.6 | Repair procedure 100HZ box and LFR (Digital Scan) | Repair procedure 100HZ box and LFR (Digital Scan) box. ------------------------------------------------------ Untill now these panels are send back with and without the metal screening box. To clarify the situation all these panels should be send back wit | ||
Philips | FL1.6 | Red, green and blue stripe in picture | Pin 8 IC7450 is 22V instead of 10V. Replace C2452 (220uF; 4822 124 41716) and D6451 (BZX79-C3V6; 5322 130 34834) | ||
Philips | FL1.6 | Red background on right side. | Check C2395 (22nF) on SSP (4822 122 32863). | ||
Philips | FL1.6 | Production modification TDA4680 supply | Production modification TDA4680 supply -------------------------------------- Jumper 9481 is replaced with a diode type BAT85 4822 130 31983 cathode to pin 5 of IC7430, TDA4680 on the SSP. REMARKS : Introduced production in week 9228. | ||
Philips | FL1.6 | Power supply shuts in protection mode. | Check IC7000, IC7001 (TDA1521Q; 4822 209 73311) and IC7011 (TDA1521AQ; 4822 209 63913) on the large signal panel on short circuit between pin 5 and pin 7. | ||
Philips | FL1.6 | Poor colors, no light in picture | Check IC7207 (SDA9205; 4822 209 31056). | ||
Philips | FL1.6 | PIP picture not in order. | Check R3345 (4822 111 41424) in PIP unit, check IC7755 (4822 209 63423). | ||
Philips | FL1.6 | Picture twists from top | Voltage of pin 8-IC7450 (TDA3654Q) on the LSP has raised to ca. 20 V. Check diode 6451 (BZX79/C5V6; 4822 130 80954). | ||
Philips | FL1.6 | Picture twists from top | Voltage of pin 8-IC7450 (TDA3654Q) on the LSP has raised to ca. 20 V. Check diode 6451 (BZX79/C3V6; 5322 130 34834 or BZX79/C10; 4822 130 61219) | ||
Philips | FL1.6 | Picture shuts off when set is warmed up. Sound remains. Error 3&4. | Sometimes no +5Vp on LFR (proscan) box. Check D6006 (4822 130 31253; BZX55-C2V4) on LFR box. | ||
Philips | FL1.6 | Picture often dark | Check IC7201 in High End-box (SAA9042P/A; 4822 209 31851) | ||
Philips | FL1.6 | Picture disappears shortly after 30" or control does not function. | When hot, 13,5 MHz clock stops working; change the value of R3123 to 1k2. | ||
Philips | FL1.6 | Picture disappears (fly back lines), ON STEREO and DUAL LEDs blink | Check IC7430 (TDA4680). When TDA4680 is too hot there is no picture (4822 209 31592). | ||
Philips | FL1.6 | Overview of SOPS repair kits | Overview of SOPS repair kits ---------------------------- FL1.0 AG00 upto AG03 4822 310 20492 FL1.0 AG04 and higher 4822 310 31921 FL1.1 25" and 28" 4822 310 31919 FL1.1 33" 4822 310 31932 FL1.2 4822 310 31932 FL1.6 |