PhilipsFL1.2Unstable picture, horizontal jitter.Check/replace R3405 on the LSP. (4822 051 10303 for 50 Hz sets; 4822 051 10333 for 100 Hz sets).
PhilipsFL1.2Tuning does not functionResistor R3240 on LSP in V-tuning wire broken.
PhilipsFL1.2Totally inoperative.Transistors 7250 (BUX85F; 4822 130 62509) and 7251 (BC848; 4822 130 61207) in microSOPS defective. Or D6251 (LLZ-C5V6; 4822 130 80954) and R1250 (=R3230; 1 Ohm; 4822 052 10108) defective. Or T7270 (BD825; 4822 130 41746) Or T7201 (BC857C; 5322 130 427
PhilipsFL1.2Total inoperative, leds blinking, error 99Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the Large signal panel. Replace by a 3kV15 HR-R capacitor if possible: 820pF 4822 126 13152 1nF 4822 126 13153 1,2nF 4822 126 13154 1,5nF 4822 126 13155 1,8nF 4822 126 13156 2,
PhilipsFL1.2Ticking noise and line in pictureTransistor 7381 (BC848C; 5322 130 42136) defective when hot.
PhilipsFL1.2The +141 is about 110V instead of 141VIt is recommended to replace the SOPS PWB (4822 212 23755).
PhilipsFL1.2Synchronization, picture disappearsD6703 and T7704 defective on picture tube panel.
PhilipsFL1.2Stripes in picture in 36" setsThe following production change has been introduced to reduce stripes in receivers with serial numbers AG039143 or higher. 1) Apply a shorting link between pins 15 and 16 of LOT (5555). 2) Cut away the earth lead between connectors S03 and L03 (pin 1
PhilipsFL1.2Spook in pictureUse special antenna cables. Codenumbers: 4822 321 61224 PAL 1 meter 4822 321 61225 PAL 2 meter 4822 321 61226 SECAM 1 meter 4822 321 61227 SECAM 2 meter
PhilipsFL1.2Spoke on 134,25 and 287,25 MHz in proscan sets.Spoke on above mentioned frequency can be solved by adding two capacitors of 33pF (5322 122 32072) on the LFR box. - between pin 10 of H22 and earth (pin 5 of H22) (CVBS). - between pin 7 of H21 and earth (pin 4 of H21) (TXT INT).
PhilipsFL1.2Sometimes in protection, or hor. width variesCheck or resolder on LSP the pins of E/W bridge coil 5521.
PhilipsFL1.2Severe Moire patterningMost modern Colour Televisions use Automatic Gray Scale Tracking and while the setting of the G1 may not seem to have a major effect on the picture brightness on a modern set, incorrect adjustment can have the effect of causing severe Moire patterning if
PhilipsFL1.2Set can only be operated with Remote ControlCheck whether "Child Lock" is disabled. To check this, see "Frequently Asked Questions", "How to disable Child Lock".
PhilipsFL1.2SAT box TXTSAT box TXT ----------- Modification: item 1802 changed into 4822 242 81427 (7,2 MHz FC >= +95kHz) item 1808 changed into 4822 242 81428 (7,2 MHz FC >= -95kHz) Remark: 4822 242 81429 has a blue marker 4822 242 81428 has a red marker Prod
PhilipsFL1.2SAT box TXTSAT box TXT ----------- Modification: item 3333 added 4822 116 52284 (47k) Remark: mounted between pin 11 of IC7330 and L5350. Reason: pull-up resistor needed for D2sync of the TPU (TPU error) Production intro date: week 9234.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.