Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsFL1.1AALine prot cct operatingCrack in print near scan coils plug
PhilipsFL1.1AAINT SHUTDOWN ( LIGHTS FLASHING )D6373 ( 18v ZENER )
PhilipsFL1.1AAInt goes into prot mode - st/by, mute & stereo LEDs flashingD6376 18v zener sm
PhilipsFL1.1AAChirps at sw on then goes into prot modeTransistors 7542 & 7540 in E-W cct s/c
PhilipsFL1.17Wrong synchronization, unstable colorsD6417 on the LSP dependent on temperature, check/replace (4822 130 81223)
PhilipsFL1.17Wrong service batch of ST24C08CB1 memory IC'sWrong service batch of ST24C08CB1 memory IC's 4822 209 32283 ------------------------------------------------------------ Temporarily a wrong batch of EAROM's has been delivered, causing the fault "NVM MEMORY NOT WRITE PROTECTED" after replacing the EAROM
PhilipsFL1.17Wrong options/no options in memory; several functions do not work.Re-adjust the options and implement the IIC-bus protection (MC33164). See service information FL1 93.02
PhilipsFL1.17Vertical shift is difficult to adjust.It is recommended to add R3471 (2K2; 4822 041 20222) REMARKS : Introduced in production in week 9337.
PhilipsFL1.17Various faults can be observed.Check the earth connection from the SSP: connect earth tuner with earth line output transformer (LSP) to find-out whether the problem is solved. Check connectors L02 and S02 pins 1,2 (sometimes only 7 wires are used in the connector)
PhilipsFL1.17Unstable picture, horizontal jitter.Check/replace R3405 on the LSP. (4822 051 10303 for 50 Hz sets; 4822 051 10333 for 100 Hz sets).
PhilipsFL1.17Tuning does not functionResistor R3240 on LSP in V-tuning wire broken.
PhilipsFL1.17Totally inoperative.Transistors 7250 (BUX85F; 4822 130 62509) and 7251 (BC848; 4822 130 61207) in microSOPS defective. Or D6251 (LLZ-C5V6; 4822 130 80954) and R1250 (=R3230; 1 Ohm; 4822 052 10108) defective. Or T7270 (BD825; 4822 130 41746) Or T7201 (BC857C; 5322 130 427
PhilipsFL1.17Total inoperative, leds blinking, error 99Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the Large signal panel. Replace by a 3kV15 HR-R capacitor if possible: 820pF 4822 126 13152 1nF 4822 126 13153 1,2nF 4822 126 13154 1,5nF 4822 126 13155 1,8nF 4822 126 13156 2,
PhilipsFL1.17Ticking noise and line in pictureTransistor 7381 (BC848C; 5322 130 42136) defective when hot.
PhilipsFL1.17Synchronization, picture disappearsD6703 and T7704 defective on picture tube panel.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.