Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsFL1.17East/West failure in cold condition.Replace C2611 by 1uF (4822 121 51319) on LSP. REMARKS : Introduced in production in week 9332.
PhilipsFL1.17Dark picture, only green led, no menu or OSD.+5V supply was 4,1V. Voltage D6551 was 4,3V instead of 5,6V. Check/replace D6551 (4822 130 80954).
PhilipsFL1.17Crazy behaviour: No response from RC or controls.Other phenomenas: volume up/down, spontanuous service mode etc. etc. in areas with TOP-teletext. Replace control software by replacing EPROM IC7002 to version V83 (4822 900 10506). For easy mounting also the controlboard 7115 (on SSP) can be replaced by
PhilipsFL1.17Crazy behaviour: No response from RC or controls.Other phenomenas: volume up/down, spontanuous service mode etc. etc. in areas with TOP-teletext. Replace control software by replacing EPROM IC7002 to version V83 (4822 900 10506). For easy mounting also the controlboard 7115 (on SSP) can be replaced by
PhilipsFL1.17Crazy behaviour: No response from RC or controls.Other phenomenas: volume up/down, spontanuous service mode etc. etc. in areas with TOP-teletext. Replace control software by replacing EPROM IC7002 to version V82 (4822 900 10423). For easy mounting also the controlboard 7115 (on SSP) can be replaced by
PhilipsFL1.17Correction to the Service ManualCorrection to the Service Manual -------------------------------- In circuit diagram B on page 7 of the service manual FL1.14/FL2.14/FL1.16/FL2.16 and FL 1.17 the resistors 3624 and 3625 are not drawn. These resistors should be drawn on the position of 96
PhilipsFL1.17Correction to service manual FLx.14/16/17Correction to service manual FLx.14/16/17 and FLx.24/26/27. ----------------------------------------------------------- The code number of position 1200 (fuse 3,15 A) is wrong. The correct code number is 4822 070 33152. This fuse is situated on the LSP i
PhilipsFL1.17Correction to Service ManualCorrection to Service Manual ---------------------------- In service manual FL1/2.14, FL1/2.16, FL1.17 AA the code number of the Scavem amplifier panel is wrong. The correct code number for this panel is 4822 212 31469. REMARKS : The code number
PhilipsFL1.17Correction to service information FL 95.01Correction to service information FL 95.01 ------------------------------------------ Correction in the overview of 100Hz and Proscan boxen. The replacement for service code 4822 212 30534 must be 4822 212 31231 The replacement for service code 4822 21
PhilipsFL1.17Correction to Product Survey 1996-4Correction to Product Survey 1996-4 (4822 727 21505) ---------------------------------------------------- On page PCS 41989 is mentioned at: FL1.10 AG11 and higher: Control panel 4822 212 31708 FL1.17 AG20 : Control panel 4822 212 31708 FL
PhilipsFL1.17Colour loss at photofinish and scan.Change position 6003 on the ECO-box into a LL4148 (4822 130 80446). REMARKS : Introduced in production in week 9424.
PhilipsFL1.17Colored picture or picture is green/red, fly-back linesCheck zenerdiode 6450 on pin 19-IC7430 on the LSP. New diode must be Philips (Telefunken does not work), 4822 130 81512
PhilipsFL1.17BUX85F in mikroSOPS defectiveChange the value of C2260 to 4n7F, replace 7270 with transistor BD825 (4822 130 41746).
PhilipsFL1.17Both languages can be heard by Dual Nicam signalsFor FL1-PTV change the software into V89; 4822 900 10732 For all other FL sets change the software into V88; 4822 900 10723 REMARKS :Introduced in production from week 9614 onwards.
PhilipsFL1.17Blank picture. OSD not synchronised and too large, no TXT.Check/replace memory IC 7900 (ST24C08CB1; 4822 209 32283).



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads