Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | FL1.14 | Unstable picture, horizontal jitter. | Check/replace R3405 on the LSP. (4822 051 10303 for 50 Hz sets; 4822 051 10333 for 100 Hz sets). | ||
Philips | FL1.14 | Tuning does not function | Resistor R3240 on LSP in V-tuning wire broken. | ||
Philips | FL1.14 | Totally inoperative. | Transistors 7250 (BUX85F; 4822 130 62509) and 7251 (BC848; 4822 130 61207) in microSOPS defective. Or D6251 (LLZ-C5V6; 4822 130 80954) and R1250 (=R3230; 1 Ohm; 4822 052 10108) defective. Or T7270 (BD825; 4822 130 41746) Or T7201 (BC857C; 5322 130 427 | ||
Philips | FL1.14 | Total inoperative, leds blinking, error 99 | Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the Large signal panel. Replace by a 3kV15 HR-R capacitor if possible: 820pF 4822 126 13152 1nF 4822 126 13153 1,2nF 4822 126 13154 1,5nF 4822 126 13155 1,8nF 4822 126 13156 2, | ||
Philips | FL1.14 | Ticking noise and line in picture | Transistor 7381 (BC848C; 5322 130 42136) defective when hot. | ||
Philips | FL1.14 | Synchronization, picture disappears | D6703 and T7704 defective on picture tube panel. | ||
Philips | FL1.14 | Supply switch-off sometimes | Check the +5 stand-by. This voltage has to be 5.5V and may not vary. When the voltage drops below 5.2V the set switches-off. Cure: check D6266 for leackage (BZX79/F6V8; 4822 130 34278) or check T7268 for leackage (BD943F; 4822 130 62742). The 5.5V is meas | ||
Philips | FL1.14 | Supply +5V too low, black horizontal bar in picture. Bad sync. | Check/replace IC7551 (LM358N; 4822 209 70672) | ||
Philips | FL1.14 | Spook in picture | Use special antenna cables. Codenumbers: 4822 321 61224 PAL 1 meter 4822 321 61225 PAL 2 meter 4822 321 61226 SECAM 1 meter 4822 321 61227 SECAM 2 meter | ||
Philips | FL1.14 | Spoke on 134,25 and 287,25 MHz in proscan sets. | Spoke on above mentioned frequency can be solved by adding two capacitors of 33pF (5322 122 32072) on the LFR box. - between pin 10 of H22 and earth (pin 5 of H22) (CVBS). - between pin 7 of H21 and earth (pin 4 of H21) (TXT INT). | ||
Philips | FL1.14 | Sometimes vibration in vertical direction. | Replace C2410 (150nF 5%; 4822 121 41854) on LSP. | ||
Philips | FL1.14 | Shuts off and on again on Pr.nr. 1 after 3 hours. | D6272 (BZX55B5V6) interruption when it becomes hot. | ||
Philips | FL1.14 | Severe Moire patterning | Most modern Colour Televisions use Automatic Gray Scale Tracking and while the setting of the G1 may not seem to have a major effect on the picture brightness on a modern set, incorrect adjustment can have the effect of causing severe Moire patterning if | ||
Philips | FL1.14 | Set sometimes goes in STAND-BY and immediately switches ON again. | Replace position IC7120 on LFR box (PCF83C652P/AB/043) by P83C652FFP/50 V34D (4822 209 33289). REMARKS : Introduced in production in week 9337. | ||
Philips | FL1.14 | Set inoperative only red or green LED. Supply was 141V but no EHT. | Line drive puls for T7506 (2SC4288A) too low. L5503 defective (Line drive coil; 4822 157 63252) |