Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsFL1.14Unstable picture, horizontal jitter.Check/replace R3405 on the LSP. (4822 051 10303 for 50 Hz sets; 4822 051 10333 for 100 Hz sets).
PhilipsFL1.14Tuning does not functionResistor R3240 on LSP in V-tuning wire broken.
PhilipsFL1.14Totally inoperative.Transistors 7250 (BUX85F; 4822 130 62509) and 7251 (BC848; 4822 130 61207) in microSOPS defective. Or D6251 (LLZ-C5V6; 4822 130 80954) and R1250 (=R3230; 1 Ohm; 4822 052 10108) defective. Or T7270 (BD825; 4822 130 41746) Or T7201 (BC857C; 5322 130 427
PhilipsFL1.14Total inoperative, leds blinking, error 99Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the Large signal panel. Replace by a 3kV15 HR-R capacitor if possible: 820pF 4822 126 13152 1nF 4822 126 13153 1,2nF 4822 126 13154 1,5nF 4822 126 13155 1,8nF 4822 126 13156 2,
PhilipsFL1.14Ticking noise and line in pictureTransistor 7381 (BC848C; 5322 130 42136) defective when hot.
PhilipsFL1.14Synchronization, picture disappearsD6703 and T7704 defective on picture tube panel.
PhilipsFL1.14Supply switch-off sometimesCheck the +5 stand-by. This voltage has to be 5.5V and may not vary. When the voltage drops below 5.2V the set switches-off. Cure: check D6266 for leackage (BZX79/F6V8; 4822 130 34278) or check T7268 for leackage (BD943F; 4822 130 62742). The 5.5V is meas
PhilipsFL1.14Supply +5V too low, black horizontal bar in picture. Bad sync.Check/replace IC7551 (LM358N; 4822 209 70672)
PhilipsFL1.14Spook in pictureUse special antenna cables. Codenumbers: 4822 321 61224 PAL 1 meter 4822 321 61225 PAL 2 meter 4822 321 61226 SECAM 1 meter 4822 321 61227 SECAM 2 meter
PhilipsFL1.14Spoke on 134,25 and 287,25 MHz in proscan sets.Spoke on above mentioned frequency can be solved by adding two capacitors of 33pF (5322 122 32072) on the LFR box. - between pin 10 of H22 and earth (pin 5 of H22) (CVBS). - between pin 7 of H21 and earth (pin 4 of H21) (TXT INT).
PhilipsFL1.14Sometimes vibration in vertical direction.Replace C2410 (150nF 5%; 4822 121 41854) on LSP.
PhilipsFL1.14Shuts off and on again on Pr.nr. 1 after 3 hours.D6272 (BZX55B5V6) interruption when it becomes hot.
PhilipsFL1.14Severe Moire patterningMost modern Colour Televisions use Automatic Gray Scale Tracking and while the setting of the G1 may not seem to have a major effect on the picture brightness on a modern set, incorrect adjustment can have the effect of causing severe Moire patterning if
PhilipsFL1.14Set sometimes goes in STAND-BY and immediately switches ON again.Replace position IC7120 on LFR box (PCF83C652P/AB/043) by P83C652FFP/50 V34D (4822 209 33289). REMARKS : Introduced in production in week 9337.
PhilipsFL1.14Set inoperative only red or green LED. Supply was 141V but no EHT.Line drive puls for T7506 (2SC4288A) too low. L5503 defective (Line drive coil; 4822 157 63252)



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads