SintomaCausaSoluçãoPor:
PhilipsFL1.14JitterIn PIP unit change the value of R3336 to 4k7.
PhilipsFL1.14How to enable/disable "Child Lock"Press "MENU" button on Remote Control. When the menu appears on the screen, you select "SPECIAL FEATURES" (this expression is language dependent) Within "SPECIAL FEATURES", the "CHILD LOCK" can be enabled or disabled.
PhilipsFL1.14Four dark bars over the picture.The +5 volt was 5.6 volt instead of 5.1 volt. Check/replace IC7551 (4822 209 70672).
PhilipsFL1.14Extension frequency range SATELLITE receptionExtension frequency range SATELLITE reception --------------------------------------------- Only for sets with SAT box: In the present FL sets with a SAT box the frequency range is: with SF914 tuner 950 - 1750 MHz with SF916 tuner 950 - 2000 MHz (optio
PhilipsFL1.14Deflection unstable when switching from panorama to wide screen.The following items on the DAF panel change: - C2860 changed into 470pF 2kV (4822 126 12267) - C2861 changed into 560pF 2kV (4822 126 12239) - R3301 and R3302 changed into VDR (4822 116 21221) REMARKS : Introduced in production from wee
PhilipsFL1.14Deflection unstable when switching from panorama to wide screen.The following items on the DAF panel change: - C2860 changed into 470pF 2kV (4822 126 12267) - C2861 changed into 560pF 2kV (4822 126 12239) - R3301 and R3302 changed into VDR (4822 116 21221) REMARKS : Introduced in production from wee
PhilipsFL1.14Dark picture, only green led, no menu or OSD.+5V supply was 4,1V. Voltage D6551 was 4,3V instead of 5,6V. Check/replace D6551 (4822 130 80954).
PhilipsFL1.14Crazy behaviour: No response from RC or controls.Other phenomenas: volume up/down, spontanuous service mode etc. etc. in areas with TOP-teletext. Replace control software by replacing EPROM IC7002 to version V82 (4822 900 10423). For easy mounting also the controlboard 7115 (on SSP) can be replaced by
PhilipsFL1.14Correction to service manual FLx.14/16/17Correction to service manual FLx.14/16/17 and FLx.24/26/27. ----------------------------------------------------------- The code number of position 1200 (fuse 3,15 A) is wrong. The correct code number is 4822 070 33152. This fuse is situated on the LSP i
PhilipsFL1.14Correction to Service ManualCorrection to Service Manual ---------------------------- In service manual FL1/2.14, FL1/2.16, FL1.17 AA the code number of the Scavem amplifier panel is wrong. The correct code number for this panel is 4822 212 31469. REMARKS : The code number
PhilipsFL1.14Correction to service information FL 95.01Correction to service information FL 95.01 ------------------------------------------ Correction in the overview of 100Hz and Proscan boxen. The replacement for service code 4822 212 30534 must be 4822 212 31231 The replacement for service code 4822 21
PhilipsFL1.14Correction of diagram M` of Service manualCorrection of diagram M` of Service manual ------------------------------------------ The diagram/partslist of the LFR (digital scan) box shows IC7244 typenumber N74F74D. However on this position an IC with typenumber N74F125D (5322 209 61857) is used.
PhilipsFL1.14CorrectionCorrection ---------- The code number of the LFR (digital scan) box FL1.14 36" mentioned in the Service Manual, Chassis FL1.14, FL2.14, FL1.16, FL2.16 and FL1.17, is not correct. Instead of 4822 212 30587 it should be 4822 212 30857. Chassis manual: GB
PhilipsFL1.14Colored picture or picture is green/red, fly-back linesCheck zenerdiode 6450 on pin 19-IC7430 on the LSP. New diode must be Philips (Telefunken does not work), 4822 130 81512
PhilipsFL1.14BUX85F in mikroSOPS defectiveChange the value of C2260 to 4n7F, replace 7270 with transistor BD825 (4822 130 41746).



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.