Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | FL1.1 | Violet back color | Change the values of R3163 (470 Ohm) and R3165 (470 Ohm) to 1kOhm in High End Box. | ||
Philips | FL1.1 | Vertical deflection in lower part picture disturbed. | Check/replace vertical amplifier IC7450 on LSP (4822 209 73308). | ||
Philips | FL1.1 | Vertical deflection in lower part picture disturbed. | Check/replace vertical amplifier IC7450 on LSP (4822 209 73308). | ||
Philips | FL1.1 | Unstable picture, horizontal jitter. | Check/replace R3405 on the LSP. (4822 051 10303 for 50 Hz sets; 4822 051 10333 for 100 Hz sets). | ||
Philips | FL1.1 | Txt does not work, lines | Diode 6200 in High-End-Box defective. | ||
Philips | FL1.1 | Txt does not work from time to time | Pin 8-IC7201 poorly soldered. IC7201 (SAA9042) defective. | ||
Philips | FL1.1 | Tuning does not function | Resistor R3240 on LSP in V-tuning wire broken. | ||
Philips | FL1.1 | Totally inoperative. | Transistors 7250 (BUX85F; 4822 130 62509) and 7251 (BC848; 4822 130 61207) in microSOPS defective. Or D6251 (LLZ-C5V6; 4822 130 80954) and R1250 (=R3230; 1 Ohm; 4822 052 10108) defective. Or T7270 (BD825; 4822 130 41746) Or T7201 (BC857C; 5322 130 427 | ||
Philips | FL1.1 | Total inoperative, leds blinking, error 99 | Check and replace if necessary C2504 and/or 2505 (2kV HRR) on the Large signal panel. Replace by a 3kV15 HR-R capacitor if possible: 820pF 4822 126 13152 1nF 4822 126 13153 1,2nF 4822 126 13154 1,5nF 4822 126 13155 1,8nF 4822 126 13156 2, | ||
Philips | FL1.1 | Ticking noise and line in picture | Transistor 7381 (BC848C; 5322 130 42136) defective when hot. | ||
Philips | FL1.1 | The +141 is about 110V instead of 141V | It is recommended to replace the SOPS PWB (4822 212 23749). | ||
Philips | FL1.1 | Synchronization, picture disappears | D6703 and T7704 defective on picture tube panel. | ||
Philips | FL1.1 | Synchronization fault, "temperature drift" | Change the value of R3132 (1k5) to 1k2 in High End Box. | ||
Philips | FL1.1 | STUCK IN STBY SWITCHED FROM REMOTE LIGHTS FLASH | C2504 USUALLY 1nF 2kv | ||
Philips | FL1.1 | Stuck in prot mode | C2504 2n2 2kv, line shift trs 7512 & 7513 |