PhilipsCP90Power supply will not start up when set is warmD6670 (IN4148) was found to be defective when warm. After replacing this Diode normal operation was restored.
PhilipsCP90poor line lin in centreD6609 & 6610 faulty (checked ok)
PhilipsCP90Pic takes long time to come onC2265 0µ1 decoupler from pin 24 TDA3561A
PhilipsCP90Patterning on RF.Check power supply +19V. If incorrect replace C2691 (330uF; 4822 124 41693).
PhilipsCP90Only half an inch of field scan in centre.Chassis return res R3582 ( 3.3R ) o/c.
PhilipsCP90off with whistleno ht on dummy load - C2703 330µ to pin 10 of chopper tfmr
PhilipsCP90off - mains fuse blownBUT11AF chopper tr breaking down under load
PhilipsCP90No vertical deflectionReplace TS7571 and TS7573 (BD939F; 4822 130 42681)
PhilipsCP90No synchronizationCheck/replace U 1040 (4822 212 22739)
PhilipsCP90No sound/pic - crt htrs alightNo 6v to micro - D6733 BAV19 o/c
PhilipsCP90No sound, picture OKReplace IC 7101 (TDA 8190; 4822 209 70872)
PhilipsCP90No sound, picture OKCheck/replace bus BU 5 (4822 267 60188)
PhilipsCP90No sound or raster - shows F1 in displayT7739 BC548 o/c
PhilipsCP90No remote functions.Photodiode D6960 dry-jointed.
PhilipsCP90No picture.Tr7619 ( BUD11 ) check C2619 ( 1nF ) & C2610



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.