Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
PhilipsCP110R/C has low gainC2967 100µ 10v in R/C receiver
PhilipsCP110PULSING IN AND OUT OF SBY UNTILL WARMCHECK SMALL SUBPANEL FOR FAULTS ESP 100mfd
PhilipsCP110Pulses in /out of st/by at sw on100µ cap on separate over volts prot panel for 15v supply
PhilipsCP110PSU trips after rebuildTr7727 BD438 in opto coupler cct
PhilipsCP110Power supply starts slowly (after 1 min)Check C2690 (100 uF 63V; 4822 124 40255) located on over-volt sub panel
PhilipsCP110Power supply destructs or does not operate; BUT11AF failure.* Check/replace: IC7669 - TEA1039 codenr. 4822 209 83104 T7665 - BUT11AF codenr. 4822 130 42679 T7666 - BC337 codenr. 4822 130 40855 IC7670 - CNX82A codenr. 4822 130 10025 * Check if damaged or changed value resistors 3658 and 3659 * Change C2
PhilipsCP110Power supply destructs or does not operate; BUT11AF failure.Check/replace position - 3653, and bridge rectifier D6657/8/9/60 - BYD14J; 4822 130 31933.
PhilipsCP110POWER SUPP RUNS BUT NO EHT , DISPLAY SHOWS " 88" , AD6901 ( AFTER REPLACING BACKUP BATTERY )
PhilipsCP110Poor start up from coldC2690 100µ 50v on overvolts sub panel
PhilipsCP110POOR REMOTE RANGEC2967 100uF 10v O/C INSIDE REMOTE CAN
PhilipsCP110Pincushion distortion.Check/replace C2610 - 7.5nF 2 kV 4822 121 43065
PhilipsCP110PICTURE PULSES ON AND OFFTR7413 OR R3415 470k ON TUBE BASE
PhilipsCP110PICTURE FLASHES CYAN OR GREEN WHEN WARMR3415 ON TUBE PCB 470k
PhilipsCP110Picture blinking (during the first 30 seconds).Transistor 7413 (4822 130 40937) or R3415 on picture tube panel is defective.
PhilipsCP110Pic flashes on & off at sw on, gradually improving Degaussing therm or R3415 470k o/c on crt base



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads