Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | CP110 | R/C has low gain | C2967 100µ 10v in R/C receiver | ||
Philips | CP110 | PULSING IN AND OUT OF SBY UNTILL WARM | CHECK SMALL SUBPANEL FOR FAULTS ESP 100mfd | ||
Philips | CP110 | Pulses in /out of st/by at sw on | 100µ cap on separate over volts prot panel for 15v supply | ||
Philips | CP110 | PSU trips after rebuild | Tr7727 BD438 in opto coupler cct | ||
Philips | CP110 | Power supply starts slowly (after 1 min) | Check C2690 (100 uF 63V; 4822 124 40255) located on over-volt sub panel | ||
Philips | CP110 | Power supply destructs or does not operate; BUT11AF failure. | * Check/replace: IC7669 - TEA1039 codenr. 4822 209 83104 T7665 - BUT11AF codenr. 4822 130 42679 T7666 - BC337 codenr. 4822 130 40855 IC7670 - CNX82A codenr. 4822 130 10025 * Check if damaged or changed value resistors 3658 and 3659 * Change C2 | ||
Philips | CP110 | Power supply destructs or does not operate; BUT11AF failure. | Check/replace position - 3653, and bridge rectifier D6657/8/9/60 - BYD14J; 4822 130 31933. | ||
Philips | CP110 | POWER SUPP RUNS BUT NO EHT , DISPLAY SHOWS " 88" , A | D6901 ( AFTER REPLACING BACKUP BATTERY ) | ||
Philips | CP110 | Poor start up from cold | C2690 100µ 50v on overvolts sub panel | ||
Philips | CP110 | POOR REMOTE RANGE | C2967 100uF 10v O/C INSIDE REMOTE CAN | ||
Philips | CP110 | Pincushion distortion. | Check/replace C2610 - 7.5nF 2 kV 4822 121 43065 | ||
Philips | CP110 | PICTURE PULSES ON AND OFF | TR7413 OR R3415 470k ON TUBE BASE | ||
Philips | CP110 | PICTURE FLASHES CYAN OR GREEN WHEN WARM | R3415 ON TUBE PCB 470k | ||
Philips | CP110 | Picture blinking (during the first 30 seconds). | Transistor 7413 (4822 130 40937) or R3415 on picture tube panel is defective. | ||
Philips | CP110 | Pic flashes on & off at sw on, gradually improving | Degaussing therm or R3415 470k o/c on crt base |