Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | CP110 | No colour. | Check/replace C2265/2266 - 100nF. | ||
Philips | CP110 | Modification | Modification The RC5 receiver 4822 212 22746 is not available anymore. For that reason the circuit diagram, PCB layout and partslist is published in service information CP110 97.01 Codenr. 4822 727 21554 | ||
Philips | CP110 | Memory loss of some pre-programmed programmes. | After reprogramming other pre-programmes disappear after some weeks.
Problem may occur in areas with heavy spikes on the mains in sets without peak voltage protection panel (sets with serial numbers | ||
Philips | CP110 | Lower half of picture cramped with lower half missing. | Check R3572 (1.5 Ohm) open circuit. This resistor is connected between the emitters of the frame output transistors. | ||
Philips | CP110 | Low HT at sw on (120v instead of 143v) | sound 'stuttery' - C2890 100µ 50v on stand up panel on psu hi esr | ||
Philips | CP110 | Lines swirling across pic & no stopping in chan search | C2671 1500µ 15v smoother | ||
Philips | CP110 | line tearing | Tr7542 BC857C s/c | ||
Philips | CP110 | Line collapse to 2" & dull raster | D6610 BY208 s/c, R3599 o/c on crt base | ||
Philips | CP110 | Intermittent HT shutdown | A production change is being introduced increasing the value of R3661 from 3R3 to 6R8 (code no. 4822 116 51876). In addition, the value of C2406 is increased from 100n to 10uF 250V (code no. 4822 124 22223). Reason: To reduce the incidence of spontane | ||
Philips | CP110 | Intermittent HT shutdown | A production change is being introduced increasing the value of R3661 from 3R3 to 6R8 (code no. 4822 116 51876). In addition, the value of C2406 is increased from 100n to 10uF 250V (code no. 4822 124 22223). Reason: To reduce the incidence of sponta | ||
Philips | CP110 | Intermittent fading of picture | Check/resolder the G2 connection to the CRT base panel. | ||
Philips | CP110 | Intercarrier-hum | Replace filter 1103 (5.5 Mc 4822 242 70714) | ||
Philips | CP110 | int various faults - bright, pulsing, st/by, dead | Chopper tfmr u/s - int internally | ||
Philips | CP110 | Int off briefly - esp when tapped | Dy joints metalwork/heatsink by chopper & loptr | ||
Philips | CP110 | INT DEAD | TRT630 BC337 LINE DRIVER OC |