Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | CM11342 | Dead - squealing noise from PSU. | No 128v rail , R3412 ( 33k ) o/c. | ||
Philips | CM11342 | Cutting out Int. | Poor connection on scan coil plug | ||
Philips | CF1 | Tripping | C2322 47µ HT cap was o/c | ||
Philips | CF1 | Rolling - no field sync | C2377 10µ o/c, also replace C2368 & C2369 4µ7 63v | ||
Philips | CF1 | ROLLING | C2377 10uF | ||
Philips | CF1 | Poor line sync from cold & jitter/field roll | C2368 4µ7 low cap connected to pin 6 IC7375 TDA2577A timebase gen chip | ||
Philips | CF1 | Patterning on lh side of screen | C2484 4µ7 connected to emitter E-W mod driver tr faulty | ||
Philips | CF1 | No sync, sound with fb lines | TDA2577 sync/timebase chip | ||
Philips | CF1 | NO SYNC NO SOUND & FLYBACK LINES ON SCREEN | TDA2577A DO NOT USE TDA2577 | ||
Philips | CF1 | No signals or raster - foreign radio only | R3585 1R0 o/c in 12v line (on crt pcb) | ||
Philips | CF1 | No line o/p - foreign radio only | R3502 5R6 o/c (under crt neck) | ||
Philips | CF1 | No colour - may be int | Check ref osc freq & TDA3560/N3 chip by substitution | ||
Philips | CF1 | Lum missing from cold | DL2 delay line faulty | ||
Philips | CF1 | Low contrast & brightness | R3600 18k in beam lim cct o/c | ||
Philips | CF1 | Int dead | Dry joints chopper tfmr (under screening plate) |