Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | ANUBIS-B | Drift of varicap voltage. | Delete C2606. REMARKS : Introduced in production from production code PM009223 or higher. | ||
Philips | ANUBIS-B | Correction to service manual | Correction to service manual ---------------------------- In the spare parts list of service manual ANUBIS B AA two part numbers are quoted for the line output transformer and also for the line linearity coil. The component used depends on the picture tu | ||
Philips | ANUBIS-B | Colours disappears. | Check capacitor C2269 (22nF; 4822 126 11544) on the mains PCB. | ||
Philips | ANUBIS-B | Bad picture. Picture out of focus. | Leak current in CRT socket. Replace CRT socket (4822 255 70251). | ||
Philips | ANUBIS-B | Auto contrast function not optimal. | Change: R3614 into 82k (4822 116 52304) R3633 into 270k (4822 051 10274) R3657 into 15K (4822 051 10153) R3681 into 30K (4822 116 52267) R3685 into 6k8 (4822 051 10682). REMARKS : Introduced in production in week 9242. | ||
Philips | ANUBIS-B | At switching-off, spot on the middle of the screen. | Change capacitor C2470 from 22uF into 4.7uF - 4822 124 80143 | ||
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6107 | ANUBIS-B with uC P83C054-CV6107 ------------------------------- 4822 209 33634 Hotel mode for uC P83C054-CV6107: YES Hotel mode enabling for uC P83C054-CV6107: 1. Enter the Service Default Mode 2. Enter Service Menu by pressing simultaneously "VOL | ||
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6014 | ANUBIS-B with uC P83C054-CV6014 ------------------------------- Replaced by uC P83C054-CV6107; 4822 209 33634 Hotel mode for uC P83C054-CV6014: YES Hotel mode enabling for uC P83C054-CV6014: 1. Enter the Service Default Mode 2. Enter Service Menu | ||
Philips | ANUBIS-B | ANUBIS-B with uC P83C054-CV6006 | ANUBIS-B with uC P83C054-CV6006 ------------------------------- Replaced by uC P83C054-CV6107; 4822 209 33634 Hotel mode for uC P83C054-CV6006: YES Hotel mode enabling for uC P83C054-CV6006: 1. Enter the Service Default Mode 2. Enter Service Menu | ||
Philips | ANUBIS-B | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV6012 ------------------------------------------------------ Replaced by uC P83C054-CV6018; 4822 209 33153 Hotel mode for uC P83C054-CV6012: YES Hotel TV, so always hotel mode | ||
Philips | ANUBIS-B | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV | ANUBIS-B Hotel TV (xxHTxxxx/xx) with uC P83C054-CV6018 ------------------------------------------------------ 4822 209 33153 Hotel mode for uC P83C054-CV6018: YES Hotel TV, so always hotel mode | ||
Philips | ANUBIS-B | After a while the alarm led is flashing (error 8). | Replace memory IC7685, ST24C02A (4822 209 62098) | ||
Philips | AnubisA/AB | psu squeals at sw on | LOPTx faulty also 7525 BUT11AF, 2A fuse, zener 6517 BZV85C5V1 | ||
Philips | ANUBIS-A | White distorted picture. Noise in sound. TXT wrong characters. | Check/replace IC7015 (TDA4504B; 4822 209 63107). | ||
Philips | ANUBIS-A | When switching to stand-by, picture flickers and the red LED blinks | Check/replace Zenerdiode D6568 (LLZ-F6V2; 4822 130 81147). |