Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | ANUBIS-A | No picture, sound and OSD are O.K. | Check C2460 (33nF/100V). | ||
Philips | ANUBIS-A | No picture, no sound | In case of a dead set Anubis A, it is recommended to replace the the grey LOT by a black LOT: 4822 140 10406 The grey LOT which can cause this phenomena is used in sets produced from approx november 1993 onwards until week 9436 (so built-in in Anubis A | ||
Philips | ANUBIS-A | No picture (CVBS SCART-out is OK) | Check IC7400 (TDA3653B/N1; 4822 209 60955) and R3449 (1 Ohm; 4822 052 10108) | ||
Philips | ANUBIS-A | No colour. | Track between pin 12 (IC7260) TDA4510 (4822 209 30389), C2252 (C2252; 4822 121 43526) and jumper R3306 (3k3; 4822 051 10332) interrupted. | ||
Philips | ANUBIS-A | Missing of Hyper channels during search. | Two possible solutions: 1: Change C2017 into 33uF (4822 124 42058). 2: Change C2005 into 330nF (5322 121 42661). REMARKS: Introduced in production for factory code: Solution 1: PM069203, ZB079219 and higher Solution 2: PM069207, ZB069212 and higher | ||
Philips | ANUBIS-A | Loss of VCR RF channel | Connect a zener diode BZX79-C6V2 (4822 130 34167) and a 1N4148 diode (4822 130 30621) in series (anode to anode) between pins 14 and 21 of 7015 (TDA4504). The zener diode cathode is to be connected to pin 21.The 1N4148 cathode is to be connected to pin 1 | ||
Philips | ANUBIS-A | Humm in stand-by. | Check SOPS transformer L5525 (4822 148 81121). | ||
Philips | ANUBIS-A | How to activate "Hotel mode" | Applicable for family: 8 local controls Identification on uP: /R217 Hotel Mode activation: Select program 38, then press "INSTALL" on local keyboard and "SLEEPTIMER" on remote control for at least 4 seconds (at activation a green "H" is displayed (to re | ||
Philips | ANUBIS-A | Hotel mode (de)activation for Anubis A with 3 loca | Hotel mode (de)activation for Anubis A with 3 local controls. Only for sets with 3 LOCAL CONTROLS In service information HOTEL MODE for GR1AX / Anubis A&B / TV/VCR-1 4822 727 20384 a mistake is made for activation and de-activation of the Anubis A with 3 | ||
Philips | ANUBIS-A | Horizontal width/linearity not correct. | Replace C2450. | ||
Philips | ANUBIS-A | Horizontal linearity not optimal. | Change C2450 into 560nF (4822 121 42442). REMARKS :Introduced in production for factory code: PM079220 and higher. | ||
Philips | ANUBIS-A | Flap front does not lock. | Replace door lock pos.7 (4822 278 10088). | ||
Philips | ANUBIS-A | Does not lock several stations. (AFC is too slow) | Check/replace and adjust IF detection coil L5040 (4822 157 63064). | ||
Philips | ANUBIS-A | Different TXT panels and IC's | Different TXT panels and IC's. Only for TXT versions IC 7702, on the TXT panel, and the components around it are only used in: 4 page TXT versions (IC7702 = 4822 209 31069, PCF84C81AP/098) 1 page TXT version with Spanish characters (IC 7702 = 4822 209 32 | ||
Philips | ANUBIS-A | Dark yellow picture. | Check connector L3 (picture tube panel). |