SintomaCausaSoluçãoPor:
PhilipsANUBIS-ACRT typesCRT types Some receivers were fitted with a CRT type A34JFQ40X04 in production.The standardized replacement for all 14" receivers with these chassis is the A34EAC01X45. Spacers may have been used when mounting the A34JFQ40X04 in the cabinet. These shou
PhilipsANUBIS-ACorrections on Product survey 1993 Yearbook:Corrections on Product survey 1993 Yearbook: Styling 13: - missing code number for the external antenne is 4822 303 30435
PhilipsANUBIS-ACorrection on service information SI 94.01Correction on service information SI 94.01 (4822 727 20292) In the spare parts list of the issue "play back of copy protected VCR tapes" 2 mistakes are made: 1. R3306 should be 0 ohm jumper (4822 051 10008), not 3k3 2. C2253 should be 1uF (4822 121 5131
PhilipsANUBIS-AColor missing due to wrong color identification of TDA4510.Add capacitor 2321 27pF (4822 122 31825) between pen 15-IC7250 and mass. Add capacitor 2310 100nF (4822 122 33496) mounted instead of wire 9268. REMARKS : Introduced in production for factory code PM059141, ZB069148 and higher.
PhilipsANUBIS-ACodenumber informationCodenumber information. In Service Manual Anubis A AB a wrong code is published for the UV915E/IEC tuner. The codenumber for the UV915E/IEC should be 4822 210 10448 REMARKS: PS. The codenumber for the UV915E/IEC tuner is correctly published in the Anubi
PhilipsANUBIS-AChroma flickering with play-back of copy protected tapes.On the sync part: change C 2350 into 47 nF 4822 122 32542 change C 2351 into 4,7 uF 4822 124 40246 change R 3350 into 75 kOhm 4822 051 10753 change R 3351 into 1,5 kOhm 4822 116 52243 On the Chroma part: add a capacitor of 47 nF (4822 121 43526)
PhilipsANUBIS-ACannot switch off Hotel Mode after replacement of the micro processor.For the new software version of the micro processor it is required to switch off the hotel mode feature with the aid of the remote control. However the non remote control set cannot receive the RC signals.Two possible solutions: 1) Make use of an tempora
PhilipsANUBIS-ABright picture, fly-back linesCheck/replace LOT 5445 (4822 140 10406)
PhilipsANUBIS-ABlinking led. Supply in protection.Check LOT 5445 (4822 140 10406)
PhilipsANUBIS-ABad tuning in SECAM L Accent (VHF CH: 47.75).Change R3604 into 33 ohm (4822 051 10339). REMARKS: Introduced in production for factory code PM059125, ZB049138 and higher.
PhilipsANUBIS-AANUBIS-A with 8 local controls with uC TMP47C434N-ANUBIS-A with 8 local controls with uC TMP47C434N-R217 4822 209 32171 Hotel mode for uC TMP47C434N-R217: YES Hotel mode activation for uC TMP47C434N-R217: 1.Select program 38 2.Press simultaneously "INSTALL" on local keyboard and "SLEEPTIMER" on
PhilipsANUBIS-AANUBIS-A with 8 local controls with uC TMP47C434N-ANUBIS-A with 8 local controls with uC TMP47C434N-3123. Replaced by uC TMP47C434N-R217; 4822 209 32171 Hotel mode for uC TMP47C434N-3123:
PhilipsANUBIS-AANUBIS-A with 3 local controls with uC TMP47C434N-ANUBIS-A with 3 local controls with uC TMP47C434N-3145 Replaced by uC TMP47C434N-3146; 4822 209 32117 Hotel mode for uC TMP47C434N-3145:
PhilipsANUBIS-AANUBIS-A with 3 local controls with uC TMP47C434N-ANUBIS-A with 3 local controls with uC TMP47C434N-3144 Replaced by uC TMP47C434N-3146; 4822 209 32117 Hotel mode for uC TMP47C434N-3144:
PhilipsANUBIS-AANUBIS-A TXT with 3 local controls with uC TMP47C4ANUBIS-A TXT with 3 local controls with uC TMP47C434N-R131 (ANUBIS-AAC) Replaced by uC TMP47C434N-R165; 4822 209 33275 Hotel mode for uC TMP47C434N-R131:YES Hotel mode activation for uC TMP47C434N-R131: 1.Select program 38 2.Press simultaneously "ME



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads