Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | Anubis B | No E-W corr | R3404 47R in module 110 panel o/c | ||
Philips | Anubis B | IF IC7685 REPLACED SET WILL DISPLAY NORWEGIAN AND | MENU SET "BARNLAS" TO "FRAN" ( OFF ) THEN SET MAY BE RESET | ||
Philips | Anubis B | HORIZONTAL GREY LINE ON SCREEN | C2413 10nF IN FIELD CCT | ||
Philips | Anubis B | ER4 displayed on screen - no text only lines. | 27Mhz Crystal 1701. | ||
Philips | Anubis A-AC 17PT166A | Dead - in shutdown mode | s/c across LOPTr coll & emitt - not LOPTx this time but C2450 330nF 250v scan coupling cap s/c | ||
Philips | Anubis A-AC | Ok until put into st/by when LED flashes with thumping noise | D6568 LLZF6V2 leaky in st/by cct | ||
Philips | Anubis A-AC | Flickers on high brightness with drop in HT | Tr7554 BC337A leaky | ||
Philips | Anubis A.AC | Blank raster - no sound ,OSD OK | Stuck in AV mode. Pin 18 IC7015 read 3v istead of 0v as Tr7877 never soldered | ||
Philips | Anubis A.AB | Tuning - not stopping when tuning or memorise | Ident pin on micro going leaky - req new micro | ||
Philips | Anubis A.AB | "E3" showing at bottom of screen | Cured by replacing EEPROM with a blank | ||
Philips | Anubis A AC | Narrow pic 4" wide - rest blanked out | TDA3504 vid contr chip IC7280 | ||
Philips | Anubis A AC | Dead | C2450 scan coupling cap s/c 330nF in 17/17" CRTs | ||
Philips | Anubis A AC | Blows BUT11A lop tr int | Dry joints scan coils conn plug | ||
Philips | Anubis A 52ZY3535 | To exit Demo Mode | Press Prog - & + together at sw on | ||
Philips | Anubis A 14PT155A/05 | Dead - 95V being dragged down because the line dr tr turned hard on by 12V from pin 29 of IC7015 (TDA4504B). | LOPTx |