Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | Anubis A | Dead but blows fuse after repair kit fitted | Crack in print between pin 12 of chopper tfmr & optocoupler | ||
Philips | Anubis A | WHEN IN STBY LED FLASHES AND LOUDSPEAKER THUMPS | D6568 6v2 ZENER | ||
Philips | Anubis A | Sound no pic field collapse | TDA3653 field chip dry jointed but resoldering did not cure - replacement did | ||
Philips | Anubis A | Set works but if a bright sceen pic flickers & H.T | T7554 ( BC337 ) | ||
Philips | Anubis A | NO TEXT , "E14" ON DISPLAY | XTAL 1701 ON SAA5246 | ||
Philips | Anubis A | no sound, vision or leds - short squeak at switch on | HT =100v - no line drive or 5v from psu lopt faulty | ||
Philips | Anubis A | No sound | In perm mute as Tr7156 BC848 leaky | ||
Philips | Anubis A | No HT regulation - R3551 150R sm overheats & Tr7537 BC848C fails | Replace 3 x 36v zeners D6557 -9 & 18v zener D6555. Also LOPTx reqd replacement | ||
Philips | Anubis A | Menu settings | Reqs RC8611 remote. Select last chan by pressing TV+ or -, press VOL/P button on set then press VOL on r/c for more than 4 secs. | ||
Philips | Anubis A | Dead with whine - psu ok on dummy load | Loptx felt warm - faulty | ||
Philips | Anubis A | Dead with squealing nise - HT only 40v | PSU OK on dummy load - scan coils faulty - reqs replacement of crt also | ||
Philips | Anubis A | Dead with HT correct | R3444 5k6 feed to line driver overheating as Driver Tr turned hard on; no lt feed to IC7015 line osc chip TDA4504 from LOP stage as LOPTx faulty | ||
Philips | Anubis A | DEAD HT AT ONLY 20v INSTEAD OF 95v IF PLUG M5 REM | D6555 IN 5v SUPPLY LEAKY | ||
Philips | Anubis A | Dead apart from whistle | Loptx - tested ok on Oz loptx tester | ||
Philips | Anubis A | DEAD , BUT11 SC. | USE SERVICE KIT SBC7021 Pt No Philips 4822 310 20491 |