Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Philips3ANo NICAM sound7201 defective (4822 209 61114).
Philips3ANo 140 VRemove audio output stage (PAS) U1003, +140 Volt is present. Replace IC7200, IC7210 (TDA1514/N4; 4822 209 70938). Also mount 2 diodes P4KE30C700 (4822 209 73095) in parallel to C2228 and C2229 (polarity is not important)
Philips3AIn VHF frequencies only noise.Defective channel selector.
Philips3AHum on standbyBuild in modification 4822 212 23273 (Mounting-instructions are included)
Philips3AGoes into Standby/ProtectionCheck Transistor 7731 (BC566) for E/C short circuit (4822 130 40989).
Philips3AFlashing on picture (flasher confirming a video output fault)Solder dry joints on CRT base PWB, replace CRT base socket and clean CRT pins.
Philips3AEntering service modePress mono button on front of set & sleep timer/print on R/c. 4 dashes appear, 1st 2 digits is parameter, 2nd 2 is value.
Philips3AEast/west defective.Check D 6610 (BYW 95C; 4822 130 41602)
Philips3ADoes not function (Stand-by LED and Crispening LED blink both)Replace C2618 (1,5 nF; 4822 126 12274)
Philips3ADisplay jumps from channel to channel.Flat cable of keyboard unit is defective.
Philips3ADead.F1601 EW feed 315Ma o/c.
Philips3ADead or lines in the upper part of the screen.Replace fuse 1642 (1 A) with 1,25 A (order code 4822 253 10075) in 33" sets that has NICAM and PIP.
Philips3ADead - HT only 35vHT = 135v when lop stage dis'd - LOPTx faulty
Philips3ADeadCapacitor C2609 in line output stage.
Philips3ACushion distortion cannot be adjusted (East-West).Check diode 6610 (4822 130 41602).



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.