SintomaCausaSoluçãoPor:
Philips2ADoes not tune. Right channel number in display.In search tuning mode the tuning voltage of channel selector remains 33V. R3740 (5R6; 4822 050 25608) broken in CITAC module.
Philips2ADoes not start.Check C2670 (68nF polyester flat foil 63V). Check C2681 6,8 uF
Philips2ADestroys line TRRemove line drive TX clean pins and refit
Philips2ADead.Standby thyristor 6727 ( BT151 ) s/c.
Philips2ADead with whiningR3602 1R safety res o/c; C2602 10µ 63v s/c; R3601 5R6 safety res o/c
Philips2ADead with whiningLOPTr leaky - used BU508V; dry joints line dr tfmr
Philips2ADEAD WITH 300v COLLECTOR BUT11AFD6663 1N5062 LEAKY
Philips2ADead with 2A fuse o/c, 2 mains rects s/cReplace CNX62 optocoupler & Tr7686 BC369
Philips2ADEAD SET , OVERVOLTS THYRISTOR FIRINGC2698 ( 4.7mfd ) o.c.
Philips2ADead or int deadOK on dummy load - C206 u/s and bulging slightly
Philips2ADead - trippingOK on dummy load - LOPTx faulty tho checked ok on tester
Philips2ADead - blows LOPTr instantly at sw onTDA2579 drive chip faulty (dist line dr wform)
Philips2ADEAD APART FROM TICKING NOISED6700 6v8 ZENER SC
Philips2ADead - 300v on BUT collector.D6663 ( 1N5062 ) leaky.
Philips2ADead - 2amp fuse blown.C2664 ( 1.5nf , 1kV )



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.