Dicas Reparação PHILIPS





Pesquisa: PHILIPS

Resultados 13482

MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
Philips2ABars in picture.199V on collector TS7422. (has to be 193V). R3427 (300k; 4822 116 52268) defective (for green) R3407 (300k; 4822 116 52268) defective (for red) R3447 (300k; 4822 116 52268) defective (for blue)
Philips2AAfter flashover of picture tube, set is in protection mode.Set works again after turning on and off. Solution: Connect a 100 Ohm resistor (4822 116 52175) between gate of D6698 and junction R3698/C2698.
Philips2A140V voltage is 120V. Stand-by and EXT1 LEDs are on.Diode 6663 (1N5062; 4822 130 41275) short-circuited, IC7830 (MAB8441P/T001; 4822 209 11037) defective. REMARKS : Only for sets with CITAC module.
Philips29PW6332/05NO TEXT, NO DOLBY OR ZOOM FEATURES NOT WORKINGRESET OPTIONS USING SERVICE TOOL PRESS "ALIGN" A MENU APPEARS RESET RELEVENT OPTIONS FROM "N" TO "Y"
Philips29PT9416 MG7.1Service Mode enteringUse the standard remote control and key in a special sequence '0,6,2,5,9,6' followed by pressing the 'MENU' button. If the main menu also appears with the service menu just press 'MENU' again to clear it.. The other way is to short the two service pins on the signal panel (pins 2 and 3 of connector 0356). The advantage of this last method is that all the software protections are turned off.
Philips29PT9113CWHITE BOX BOTTOM LEFT OF SCREENAUTO SUBTITLE SELECTED SWITCH OFF FROM HANDSET
Philips29PT8444Correction to position 21 of styling 220Correction to position 21 of styling 220 of Product Survey 1999-3 (3122 785 10300 The code numbers mentioned for the aluminium columns at position 21 of styling 220 are not correct. The correct code numbers must be: 21 4822 466 12216 Aluminium colum
Philips29PT8434Correction to position 21 of styling 220Correction to position 21 of styling 220 of Product Survey 1999-3 (3122 785 10300 The code numbers mentioned for the aluminium columns at position 21 of styling 220 are not correct. The correct code numbers must be: 21 4822 466 12216 Aluminium colum
Philips29PT8424Correction to position 21 of styling 220Correction to position 21 of styling 220 of Product Survey 1999-3 (3122 785 10300 The code numbers mentioned for the aluminium columns at position 21 of styling 220 are not correct. The correct code numbers must be: 21 4822 466 12216 Aluminium colum
Philips29PT8419Corrections on service manual EM1A AAPage 4 Chapter 2: It was forgotten to mention here in this chapter that the architecture is 'hot'for a big part. E,g. deflection is 'hot', but also the middle big heatsink. So be warned. Page 16 Chapter 5: SAM-menu on right hand top side, sho
Philips29PT8319Corrections on service manual EM1A AAPage 4 Chapter 2: It was forgotten to mention here in this chapter that the architecture is 'hot'for a big part. E,g. deflection is 'hot', but also the middle big heatsink. So be warned. Page 16 Chapter 5: SAM-menu on right hand top side, sho
Philips29PT828CTRIPS FROM GREEN LED TO RED TO GREEN TO REDREPLACE IC7450, AND IC7550 ON AUDIO PCB
Philips29PT828CSTUCK IN STANDBYRESOLDER SCAN COIL PLUGS
Philips29PT6231Interference from adjacent channelCheck, and replace/change posn: 1145 (SAW filter) on chassis to 2422 549 44223 OFWK7260M For /79R, add posn: 1168, 4822 242 81572 6MHz ceramic filter REMARKS : Solution implemented in production
Philips29PT6021SDM does not work by shorting service pins.Measure pin 19 of SIMM connector 0226 on LSP, if it is 2V (normal is 1V) then add a resistor of 1K8 between pin 19 of the SIMM connector and ground. Make sure counting left from pin 1, do not use the pin no. printed on service print! See attached ph



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.