Philips | 14PV274 | Start up problems | When the set is switched on by the mains-switch while a cassette is in the set, the front LED starts blinking, but the set doesn't start. Solution: Check the primary voltage (Ubat) and adjust this for 14" sets to exactly 101.5 Volt. (See chapter 3.1.1 | ||
Philips | 14PV274 | Spare part information | If the lever inside the mains-switch is broken, the switch doesn't remain in the "ON" position. Solution: replace the switch by a new one. Improved switches of a newer production range are on stock. (4822 276 13542) | ||
Philips | 14PV274 | Modification | From production week 9725, the IC's SDA5649, SDA5649x and SDA5648 are replaced by a SDA5650 (4822 209 15504). This new IC is fully compatible with the others, but has better characteristics. In addition to this modification, R3812 on the small signal boar | ||
Philips | 14PV274 | Memory erase procedure | The contents of the memory can only be cleared via the service mode. This option is not available for end users. (Risc of destroying option codes). Service mode: press "STOP" on Remote Control and "PLAY" on the set for 5 seconds. Select the second page | ||
Philips | 14PV274 | Key set | The key set assy has been codified for all B-range TVCR's. This will allow to change the keys without having to change the complete frame. Servicenr. 4822 410 11075. Key set for: 14PV263/01/02/08/13 - 14PV264/39 - 14PV163/05 - 14PV172/01/05/08/13/39 - 14 | ||
Philips | 14PV274 | int. goes to stby on its own | replace T7687 BC547B (line drive emitter follower) | ||
Philips | 14PV274 | Codenumber correction for deck-up (IC7410) | The codenumber for the deckprocessor was wrong in the first Service Manual (4822 726 15451). In service information TVCR96-01 and in the new manual the correct codenumber is given. The codenumber for the deck-up for sets with non-turbo drive is: 4822 2 | ||
Philips | 14PV274 | Calling installation menu | The installation menu is activated by the following procedure: - switch on the set by means of the stop key. - Press simutaneously the "stop" key and the "volume -" key on the set. | ||
Philips | 14PV264/39 | Codenumber information - new software | A new software version (PTCP2-7) is available for the control uP (IC 7801). Service codenumber is 4822 209 15271. This new version is only used in the following sets: 14PV263/01, 14PV162/01, 14PV162/05, 14PV162/07, 14PV163/05, 14PV163/05H, 14PV263/01, | ||
Philips | 14PV264 | Start up problems | When the set is switched on by the mains-switch while a cassette is in the set, the front LED starts blinking, but the set doesn't start. Solution: Check the primary voltage (Ubat) and adjust this for 14" sets to exactly 101.5 Volt. (See chapter 3.1.1 | ||
Philips | 14PV264 | Modification | From production week 9725, the IC's SDA5649, SDA5649x and SDA5648 are replaced by a SDA5650 (4822 209 15504). This new IC is fully compatible with the others, but has better characteristics. In addition to this modification, R3812 on the small signal bo | ||
Philips | 14PV264 | Key set | The key set assy has been codified for all B-range TVCR's. This will allow to change the keys without having to change the complete frame.Servicenr. 4822 410 11075. Key set for: 14PV263/01/02/08/13 - 14PV264/39 - 14PV163/05 - 14PV172/01/05/08/13/39 - 14P | ||
Philips | 14PV264 | Codenumber information | The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702 | ||
Philips | 14PV263/02 | Option code: 23532 | From week 02/97 onwards the option code is printed on the typesticker. Always use this code ! For early sets without this information on the typesticker, the option code is: 23532 | ||
Philips | 14PV263/02 | New VPS IC SDA5642-6 (pos. 7840) | Since production week 9741 a new VPS IC pos. 7840 (SDA5642-6) is introduced in production. This IC is not compatible with the previous one. When ordering, look at the printing on the IC ! Old: SDA 5642-5 - codenumber 4822 209 32728 New: SDA 5642-6 - co |