Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | 14PV263/01 | Option code: 24492 | From week 02/97 onwards the option code is printed on the typesticker. Always use this code ! For early sets without this information on the typesticker, the option code is: 24492 | ||
Philips | 14PV263/01 | Codenumber information - new software | A new software version (PTCP2-7) is available for the control uP (IC 7801). Service codenumber is 4822 209 15271. This new version is only used in the following sets: 14PV263/01, 14PV162/01, 14PV162/05, 14PV162/07, 14PV163/05, 14PV163/05H, 14PV263/01, | ||
Philips | 14PV263 | Strange colours after recording. | Check chroma IC7051 (4822 209 90538). | ||
Philips | 14PV263 | Start up problems after replacing TS7352 | When TS7352 is replaced, it can happen that the set doesn't start up properly. There are 2 possible solutions for this problem: - use SGS type MTP3055E (4822 130 63726). - In case of a motorola type MTP3055V (4822 130 60838), add a 22 uH coil soldered | ||
Philips | 14PV263 | Start up problems | When the set is switched on by the mains-switch while a cassette is in the set, the front LED starts blinking, but the set doesn't start. Solution: Check the primary voltage (Ubat) and adjust this for 14" sets to exactly 101.5 Volt. (See chapter 3.1.1 | ||
Philips | 14PV263 | Spare part information | If the lever inside the mains-switch is broken, the switch doesn't remain in the "ON" position. Solution: replace the switch by a new one. Improved switches of a newer production range are on stock. (4822 276 13542) | ||
Philips | 14PV263 | Spare part information | A repair kit , containing PULLEY SHAFT + WORM SHAFT (POS. 47+48) is delivered with codenumber 4822 310 10657. This kit can be used for all TURBO- and ECO mechanisms ! | ||
Philips | 14PV263 | Set produces audible noise in stand-by | Add a small LEBL (leading edge blanking) PCB, to avoid auto oscillation of transformer 5330 (or 5331). A modification letter is included with the LEBL PCB. This PCB is available with service nr. 4822 214 12173. | ||
Philips | 14PV263 | Set produces audible noise in stand-by | Add a small LEBL (leading edge blanking) PCB, to avoid auto oscillation of transformer 5330 (or 5331). A modification letter is included with the lable PCB. This PCB is available with service nr. 4822 214 12173. Since production week 9723 this circuit is | ||
Philips | 14PV263 | Memory erase procedure | The contents of the memory can only be cleared via the service mode. This option is not available for end users. (Risc of destroying option codes). Service mode: press "STOP" on Remote Control and "PLAY" on the set for 5 seconds. Select the second page | ||
Philips | 14PV263 | Key set | The key set assy has been codified for all B-range TVCR's. This will allow to change the keys without having to change the complete frame. Servicenr. 4822 410 11075. Key set for: 14PV263/01/02/08/13 - 14PV264/39 - 14PV163/05 - 14PV172/01/05/08/13/39 - 14 | ||
Philips | 14PV263 | How to activate/de-activate "Hotel mode" | Activation: - set volume to desired level. - select programm 38. - press the STOP button of the remote control AND the STOP button of the VCR for about 5 seconds, until the message H+ appears. De-activation: - set volume to desired level. - select p | ||
Philips | 14PV263 | Correction service Manual 14PV263/01 | The indication of the small-signal PCB (page 1-3) is wrong. The right indication is PSSPP3/GPVXF. This PCB is only applied in 14PV263/01. | ||
Philips | 14PV263 | Codenumber information | Please add following codenumbers to the Service Manual: Lift-flap 14PV263/01 : 4822 443 10404 Lift-flap 14PV263/02 : 4822 443 10404 Spring for lift-flap : 4822 492 70896 | ||
Philips | 14PV263 | Codenumber information | The codenumber for the spacer between on/off switch and the knob (pos 3) is 4822 402 10702. |