Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | GR1-AL | TELA AZUL | Resistor R710 .**. | ||
Philips | GR1-AL | SOM DISTORCIDO OU FANHOSO. | APARELHOS MONITORES SAIRAM COM UM TRANSISTOR A MAIS TS625, RETIRAR. * INF *. | ||
Philips | GR1-AL | SOM DIMINUI ACIONANDO VOL+ [(DISPLAY OK)]. | Verificar ajuste da bobina 4,5mHz. * 18Mar97 MAN *. | ||
Philips | GR1-AL | SOM COM RUIDO OU FRITURA | Ver capacitor C135 (47uF) alterado. * 08Out96 ANC *. | ||
Philips | GR1-AL | SOM COM ESTALOS (CLICK, TOK). | Ver capacitor C135.**. | ||
Philips | GR1-AL | SOM BAIXO OU SEM SOM EM AV. | DIODO D012. * OUT 95 CTR *. | ||
Philips | GR1-AL | SO FICA EM STAND BY (POWER OFF). | Cristal KT923. Integrados IC997/IC900. | ||
Philips | GR1-AL | SINTONIZADOR COM POUCO GANHO | UNIDADE VARICAP (210 47017). * 13DEZ95 LAV *. | ||
Philips | GR1-AL | SINTONIA VARIANDO. | Diodos D124/D121.** Fuga no diodo D365 (5V6). * 08Nov95 ANC *. | ||
Philips | GR1-AL | SINTONIA INTERMITENTE EM UHF. | VER INF.SERVIÇO 06CT9020 IC997 C951 Verificar capacitor C102 com fuga. * 18Set96 ANC *. | ||
Philips | GR1-AL | SEM TENSAO (VO, +B, HVT, ETC). | (+70 com 0V ou muito baixo) 1º) Abrir ponto PT2, o +70V aparece, ver U550, D512, U020, D508 e circuito de proteçao (D535). Caso no apareça veja informaçoes deste Chassis como (TENS2). * 08Out96 ANC *. | ||
Philips | GR1-AL | SEM SOM. (COM OU SEM IMAGEM P/ TV, VCR). | C607/C135 TS610/TS613.** | ||
Philips | GR1-AL | SEM SINTONIA. | Ver capacitores C955/C960.**. | ||
Philips | GR1-AL | SEM SINTONIA EM UHF. | Verificar C102 com fuga. * 18Set96 ANC *. | ||
Philips | GR1-AL | SEM SINCRONISMO VERTICAL (VERT5). | Integrado IC410 Capacitores C156/C180/C181/ DiodosD180/D181 Transistor TS180.**. Alguns aparelhos tem dois capacitores a mais, um na posiçao C177 (1K8) e outro na C178 (180pF), possivel fuga. * 08Out96 ANC *. |