SintomaCausaSoluçãoPor:
PhilipsA10QUADRO CONCAVO ( ). Verificar ajuste de geometria (correcao lesteoeste). IRIS: sintoma 338, secao DFL, reparo C. * 01Fev2001 Inf IWS report Germany *.
PhilipsA10PERDE MEMORIA AO DESLIGAR. (DESPROGRAMA) Verificar capacitor 2962 4700uF (2020 021 91501), codigo IRIS 2717. * 24Out2000 EHV ST00/0071 *. Verificar modulo SSP. IRIS: sintoma 264, secao CTR, reparo N. * 01Fev2001 Inf IWS report from Germany
PhilipsA10NAO FUNCIONA EM AUDIO E VIDEO Verificar programacao do Option na pagina 99 do Manual 4806 727 17235. IRIS: sintoma 170. 02Fev2001 Inf report from France *.
PhilipsA10NAO FUNCIONA (FICA COMO DESLIGADO). Verificar diodo 6414, bobinas 5474, 5475, 5476, 5478 e 5479, 7470. * 16Out00 Inf buffer de erros do manual A10 *. Caso esteja com PTC defeituoso, verificar 3912. * 24Out2000 EHV ST00/0075 *. Interligar catodo de 6941 ao catodo de 6961, atrav
PhilipsA10MANCHAS NA IMAGEM (FALTA DE PUREZA). Verificar bobina desmagnetizadora. IRIS: sintoma 434, secao CRT, reparo C. * 02Fev2001 Inf report from S'pore *.
PhilipsA10LIGA SOZINHO. Aparelho apresenta comportamento estranho, verificar painel SSB. IRIS: sintoma 110, secao CTR, reparo A (SSB). * 02Fev2001 Inf IWS report from Germany *.
PhilipsA10LED(S) PISCANDO. (REPETITIVAMENTE) 4 vezes, verificar linha do 5V, caso necessario isole a bobina 5430 e o jump 9044 para facilitar a medida do mesmo. * 16Out00 Inf buffer de erros manual A10 *. Verificar transistor FET 7421 (4822 130 63666). IRIS: sintoma 110, secao DFL, reparo
PhilipsA10GEOMETRIA INCORRETA EM 16/9. Reajustar geometria. IRIS: sintoma 320. * 01Fev2001 Inf IWS report from France.
PhilipsA10DESLIGA LOGO APOS LIGAR. Verificar fonte de 200V, resistores 3840, 3445 e diodo 6445, 7501. * 16Out00 Inf buffer de erros manual A10 *.
PhilipsA10DESLIGA INTER. OU PROTEGE (REW 3 P/ VCR). Verificar bobina defletora, bobina de linearidade 5417, capacitores 2414/2416/2418/2419. * 16Out00 Inf buffer de erro manual A10 *.
PhilipsA10DANIFICA SEMICONDUTOR IC OU TS Transistor 7410, verificar possivel curto no TSH 5431. IRIS: sintoma 111, secao DFL, reparo A. * 01Fev2001 Inf IWS report from Germany * .
PhilipsA10CORRECAO LESTE OESTE INTERMITENTE. Verificar mola de fixacao do 7470. IRIS: sintoma 338, secao DFL, reparo A. * 01Fev2001 Inf IWS report from Germany *.
PhilipsA10COR INTERMITENTE Verificar contatos do modulo SSP (ma fixacao). IRIS: sintoma 33X, secao CPA, reparo D. * 01Fev2001 Inf IWS report from Germany *.
PhilipsA10BRANCO IRREGULAR Verificar cinescopio. IRIS: sintoma 340, secao CRT, reparo A. * Inf IWS report from Germany *.
PhilipsA10AMPLITUDE IRREGULAR EM DOUBLE WINDOW. Verificar 2501. IRIS: sintoma 336, secao DFL, reparo A (2501). * 02Fev2001 Inf IWS report from S'pore *.



Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.