Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Philips | 7CM5299 | BRILHO EM EXCESSO | SOLDA FRIA EM F601. * OUT 95 HBG *. Verificar capacitor 2602 (470k). * 02Abr97 FR *. | ||
Philips | 7CM5299 | BRANCA COM RETRAÇOS (OU ALGUMA COR FRACA). | RESISTOR 3786 (10R) NA PLACA TRC. * JUN 95 ANC *. Transistor 7722/7723 em curto, 3786 aberto. * 23Jul96 CTR * | ||
Philips | 7CM5299 | AZUL INTERMITENTE. | CAPACITOR QUEBRADO 2701 (22nF). * AGO 95 ANC *. | ||
Philips | 7CM3689 | TENSOES ACIMA DO ESPECIFICADO | RESISTORES 3129/3131. MAT ALTO, VER CAPACITOR 2423 ABERTO (5K6). * MAI 95 ANC *. | ||
Philips | 7CM3689 | TENSOES ABAIXO DO ESPECIFICADO (VO, +B,..) | Transistor 7106 alterado. * 26Fev96 ANC *. | ||
Philips | 7CM3689 | TELA ROXA (SEM VERDE) | Resistor 3340 (10e) aberto. * 26Fev96 ANC *. | ||
Philips | 7CM3689 | TELA ESCURA "PRETA" (VEJA TAMBEM BRIL4). | Resitores 3340, 3366 e 3370 (10e) abertos. * 26Fev96 ANC *. | ||
Philips | 7CM3689 | TELA CIANO (SEM VERMELHO) = VERM1 | Resistor 3363 (10e) aberto. * 26Fev96 ANC *. | ||
Philips | 7CM3689 | TELA AZUL | 7301. Trilha partida do pino 24 do integrado 7301 (LM1203). * Nov 95 ACM *. | ||
Philips | 7CM3689 | TELA AMARELA (SEM AZUL) | VERIFICAR CABO DE INTERLIGAÇAO RGB. * ABR 95 ANC *. Resistor 3370 aberto. * 26Fev96 ANC *. | ||
Philips | 7CM3689 | SEM TENSAO (VO, +B, HVT, ETC). | MAT, verificar bobina S121 aberta. * 02Abr97 FR *. | ||
Philips | 7CM3689 | SEM SINCRONISMO HORIZONTAL. | CIRCUITO INTEGRADO 7801 (HEF4538), OU AJUSTE 3819. * MAI 95 JO/ANC *. | ||
Philips | 7CM3689 | PERDE SINC. NA RES 640 X 400 - 640 X 480. | VERIFICAR INTEGRADO 7801 DANIFICADO OU RESISTOR 3819 DESAJUSTADO. * MAI 95 JO/ANC *. | ||
Philips | 7CM3689 | PERDE SINC. HOR. EM 1024X768. | INTEGRADO 7406 (MC1391). * OUT 95 ANC *. | ||
Philips | 7CM3689 | PERDE SINC. HOR. AO MUDAR CENA OU RESOLUÇAO. | AO ENTRAR NA RESOLUÇAO DE 1024 X 768, VERIFICAR TRIMPOT 3421 ALTERADO. * MAI 95 ANC *. INTEGRADO 7406 (MC1391). * OUT 95 ANC *. |